Agpo Ferroli spare parts
Original parts for all Agpo Ferroli appliances. Choose your model below for the complete parts list (often with an exploded view) and order directly.
Instalpunt supplies 313 original Agpo Ferroli parts for 94 models, with part number, price and exploded view. Order online.
- 313Spare parts
- 94Models
- €1.31From
Agpo Ferroli parts by type
Looking for a specific type of part? For each type, all Agpo Ferroli spare parts are listed with price, stock and the models they fit.
- Fans 13
- Sensors 15
- Temperature sensors and NTC sensors 9
- Flow sensors and flow switches 7
- Pumps 9
- Heat exchangers 11
- Gas valves and gas control 12
- PCBs and controls 15
- Diverter valves and hydroblocks 6
- Ignition and ionisation 7
- Siphons and condensate drains 8
- Burners 6
- Filters 7
- Valves 18
- Electrical parts 7
- Cables and wiring harnesses 8
- Gaskets and seals 36
- Pipes, tubes and hoses 22
- Insulation 9
Agpo Ferroli hot water cylinders
Agpo Ferroli boilers
- BlueHelix HiTech RRT 28C38 parts
- BlueHelix HiTech RRT 34C39 parts
- BlueSense 327 parts
- BlueSense 428 parts
- BlueSense 526 parts
- Domina C124E14 parts
- Domina C24E13 parts
- Domina F124E20 parts
- Domina F24E20 parts
- Econforte HMA234 parts
- Econforte HMA324 parts
- Econforte HMC233 parts
- Econforte HMC325 parts
- Econpact 125C44 parts
- Econpact 127A39 parts
- Econpact 127C43 parts
- Econpact 135A39 parts
- Econpact 135C44 parts
- Econpact 225C44 parts
- Econpact 235C / 5 (235C)44 parts
- Econpact 27A32 parts
- Econpact 27C (ST)35 parts
- Econpact 3-225C40 parts
- Econpact 35A32 parts
- Econpact 35C (ST)30 parts
- Econpact 50A12 parts
- Econpact 50B23 parts
- Econpact HP 225C43 parts
- Econpact HP 3 4-22540 parts
- Energy Top B160-B25044 parts
- Energy Top B80-B12528 parts
- Energy Top W12538 parts
- Energy Top W8039 parts
- Ferroli NA 23 TK5 parts
- Ferroli NAV 224 EH5 parts
- Ferroli NAV 224 T7 parts
- Ferroli NBV 224 EH5 parts
- Ferroli NBV 224 T7 parts
- Ferroli NE 1239 parts
- Ferroli NE 323 T8 parts
- Ferroli NEV 1151 parts
- Ferroli NEV 12411 parts
- Ferroli NEV 324 EH8 parts
- MegaDens 347 parts
- MegaDens 3 20044 parts
- MegaDens 3 300 Pro36 parts
- MegaDens 448 parts
- MegaDens 4 20040 parts
- MegaDens 4 300 Pro33 parts
- MegaDens 4SHR50 parts
- MegaDens 4SHR 20041 parts
- MegaDens 550 parts
- MegaDens 5 20037 parts
- MegaDens 5 300 Pro41 parts
- MegaDens 5SHR50 parts
- MegaDens 5SHR 20041 parts
- MegaDens A 300 Pro24 parts
- MegaLux 539 parts
- MegaLux 5 20020 parts
- MegaLux 621 parts
- MegaLux 6 20021 parts
- MegaLux A19 parts
- MegaStar 3C13 parts
- MegaStar 3F20 parts
- MFT 1322 (Combifort)8 parts
- MFT 522 (Combifort)7 parts
- Ultima 3 2027C46 parts
- Ultima 3S 1025C46 parts
- Ultima 4 2035C45 parts
- Ultima 4S 1035C47 parts
- Ultima 5 2038C44 parts
- Ultima A 2238C43 parts
- Xignal NAV 1424T6 parts
- Xignal NE 1323T5 parts
- Xignal NEV 1124 EF HR7 parts
- Xignal NEV 1322T6 parts
- Xignal NEV 1324 EF HR13 parts
- Xignal NEV 1324T13 parts
- Xignal NEV 324T12 parts
- Xignal NEV 722 EF HR7 parts
Agpo Ferroli district heating units
- Blue City 1006 parts
- Blue City 2006 parts
- Blue City 30016 parts
- Blue City 4008 parts
- CCS MI8 parts
- CCS OPT4 parts
- URS4 parts
- URS Elegance5 parts
- URS Elegance II7 parts
Agpo Ferroli MVHR units
Agpo Ferroli fault code? This is the part you usually need
Your Agpo Ferroli appliance is showing a fault code? Below you can see, for common codes, which part is usually the cause – ready to order.
| Fault code | What is going on | Part |
|---|---|---|
| 1 | Heating indirectly fired hot water cylinder, pump overrun: hot water mode | View pumps |
| 2 | Heat demand for central heating / pump overrun | View pumps |
| 5 | Insufficient combustion air or condensate drain blocked. | View siphons |
| A 01 | No ionisation | View electrodes |
| A 02 | Too little ionisation | View electrodes |
| A 04 | Gas valve relay defective | View gas valves |
| A 08 | Glow plug relay defective | View electrodes |
| A 1 | No ionisation signal (during ignition) | View electrodes |
| A 16 | No ionisation signal after 1 minute | View electrodes |
| A 19 | No flame extinction after gas valve closes | View gas valves |
| A 2 | High-limit thermostat tripped | View thermostats |
| A 20 | Flame detected with burner off. | View burners |
| A 3 | Excessive flue gas temperature detected 3 times within 24 hours. This sensor is fitted as standard | View sensors |
| A01 | No ionisation signal during ignition | View electrodes |
| A05 | Fan error | View fans |
| A1 | No ionisation signal during ignition | View electrodes |
| A16 | No ionisation signal after 1 minute | View electrodes |
| A2 | High-limit thermostat tripped | View thermostats |
| A25 | Fault F36 occurred more than 3 times in the last 24 hours. With fault F36 the ionisation pin is short-circuited to earth, possibly due to moisture. | View electrodes |
| A3 | Excessive flue gas temperature detected 3 times within 24 hours. This sensor is fitted as standard | View sensors |
| A41 | No water circulation: after burner ignition, 3x no rise in CH flow temperature (at least 1°C rise required after 15 sec.). | View electrodes |
| A5 | Fan error | View fans |
| C | Heat demand for central heating / pump overrun | View pumps |
| c | Heat demand for central heating / pump overrun | View pumps |
| E 04 | CH control sensor short-circuited, defective sensor, check the sensor | View sensors |
| E 23 | Glow plug short-circuited to earth | View electrodes |
| F08 | Gas valve fault. | View gas valves |
| F09 | Flue gas temperature too high: the heat exchanger sensor measures an excessive flue gas temperature for more than 2 min. | View heat exchangers |
| F10 | CH flow dual sensor fault (sensor 1): not connected or defective | View sensors |
| F14 | Outdoor sensor fault | View sensors |
| F16 | No ionisation signal after 1 minute | View electrodes |
| F36 | Ionisation pin short-circuited to earth | View electrodes |
| F39 | Outdoor sensor fault | View sensors |
| F47 | CH flow dual sensor fault (sensor 2): not connected or defective | View sensors |
| F6 | Fan error | View fans |
For guidance only: the same code can have a different cause depending on the model. Not sure? Write to us or have the appliance checked by a qualified professional.