Boiler with display and pressure gauge
Boiler fault codes

Vaillant boiler faults: fault codes, causes and parts

All 228 fault codes for Vaillant boilers, plus the faults that show no code. Type your code or choose your symptom.

In brief

A fault on a Vaillant boiler usually means that the appliance has locked out or is reporting a fault code. Note the code on the display and look it up below: for each code you will find its meaning, checks you can safely do yourself and the parts that are often checked or replaced. Frequently searched: F.22 (system water pressure too high, Defective expansion…), F.75 (no pressure jump is measured when the…), Emergency mode “Speed” (no speed signal from fan). No code? Check the water pressure (1.5 to 2 bar when cold), the power supply and the gas tap, and reset once. If the fault comes back, call in a certified gas engineer. If you smell gas, call your national gas emergency number or 112 immediately.

Most searched Vaillant faults

These are the codes that visitors to this site search for most often.

See the 25 most searched fault codes of 2026, with the figures behind them →

Vaillant boiler faults without a code on the display

Not every fault shows a code. These are the symptoms we come across most often with Vaillant appliances, with what you can check yourself before calling someone out.

No hot water, but the heating works

The boiler heats the radiators but not the tap water. Check that the hot water function is switched on in the display (on some appliances it is called DHW mode or summer mode) and that the hot water valve under the boiler is open. If the water stays cold, this usually points to a fouled or leaking DHW heat exchanger, a faulty diverter valve or a DHW sensor giving incorrect readings. View the matching parts → Read the full explanation: no hot water, six causes →

Water pressure keeps dropping

Top up to 1.5–2 bar when cold and bleed the radiators. If the pressure drops again within a few days, the expansion vessel has often lost its pre-charge or there is a small leak in the system. A pressure relief valve that keeps dripping gives the same symptom. View the matching parts → Read the full explanation: water pressure keeps dropping – expansion vessel or leak? →

Boiler shuts down and locks out

The appliance shuts down and only starts again after a reset. Reset once; if the fault comes straight back, leave the reset button alone. Repeatedly resetting a locked-out boiler is not without risk: the safety device trips for a reason. View the matching parts → Read also: is the boiler cutting out because of a sensor or overheating? →

Radiators stay cold

Check that the thermostat is calling for heat, that the radiator valves are open and that the system has enough pressure. If everything stays cold while the boiler is firing, the circulation pump is often not running or the diverter valve is stuck in the hot water position. View the matching parts → Read the full explanation: radiators stay cold →

Ticking, humming or boiling noise

A banging noise at start-up usually points to air or limescale in the heat exchanger. A humming pump may have a worn bearing. A rattling fan is often rubbing or dirty. View the matching parts → Read also: replacing the fan – what to rule out first →

Water under the boiler

Check where it is coming from: the condensate drain (siphon blocked or cracked), the pressure relief valve (pressure too high or faulty expansion vessel) or a fitting. If in doubt, switch the boiler off and close the water supply. View the matching parts → Read the full explanation: water under the boiler – condensate or a leak? →

Vaillant boiler fault codes 1 to 150 of 228

The code list is split over 2 pages. Looking for a specific code? Use the search at the top of this page: it searches all 228 codes in one go.

CodeCause
ErrInterface communication
F.00The signal from the flow temperature sensor is open circuit.
F.00Open circuit of flow NTC
F.00Open circuit of flow temperature sensor (NTC)
F.00Open circuit of central heating flow sensor
F.00Open circuit of flow temperature sensor
F.00No fault
F.01Ignition fault (no flame detection), No gas/gas tap closed, No ignition
F.01The signal from the return temperature sensor is open circuit.
F.01Open circuit of return temperature sensor
F.01Open circuit of return sensor
F.01Open circuit of return temperature sensor (NTC)
F.02The signal from the hot water connection temperature sensor is open circuit.
F.02Open circuit of DHW outlet sensor
F.02Temperature limiter > 105 °C
F.03Dry-fire protection
F.03The signal from the cylinder temperature sensor is open circuit.
F.03Open circuit of cylinder temperature sensor/domestic hot water temperature sensor
F.04Fan fault
F.04See F 1
F.05Flame signal invalid
F.05Limit fault, flow temperature too high (pump not running, voltage present)
F.05Open circuit of outside flue gas sensor
F.05Open circuit in outdoor temperature sensor
F.06Open circuit of inside flue gas sensor
F.06Flow NTC fault (the limit thermostat must be reset manually), NTC is broken, or wiring not in order, Burner control unit or pump cable defective, Radiators are closed or air in boiler or system, Pump setting too low, Flow NTC deviates or is loose:
F.06Electronics
F.07DHW NTC fault, NTC is broken, or wiring not in order
F.07Flow sensor
F.08Return sensor
F.09Domestic hot water sensor
F.09Water pressure sensor broken or wiring faulty
F.09Short circuit or open circuit of domestic hot water sensor
F.10Short circuit of flow sensor
F.10Short circuit in flow NTC
F.10Short circuit of flow sensor
F.10Short circuit of flow temperature sensor
F.10Short circuit of flow temperature sensor
F.10Return NTC broken, or wiring not in order
F.105Gas valve offset in D.052 set incorrectly
F.11Short circuit of return sensor
F.11Short circuit of return sensor
F.11Short circuit of return temperature sensor
F.11Short circuit of return temperature sensor
F.11No signal on the main PCB, Fan defective
F.12No signal on user interface
F.12Short circuit of DHW outlet sensor
F.12Short circuit at DHW outlet temperature sensor (NTC)
F.13Short circuit of cylinder temperature sensor
F.14Flow temperature greater than 95 °C
F.14Circulation problem
F.15Short circuit in outdoor temperature sensor
F.15Short circuit of outside flue gas sensor
F.16Short circuit of inside flue gas sensor
F.16Incorrect flame detection (flame visible for a short time, then lost)
F.16Short circuit in room temperature sensor
F.17Insufficient mains voltage < 170 V ~ Defective main PCB
F.18User interface fault
F.19CH NTC (flow and/or return) open circuit, Connector detached from NTC, Break in wiring, NTC defective
F.194Mains adapter of the PCB defective
F.195Variations (voltage too low) in the supply voltage
F.196Supply voltage too high
F.20Maximum limit protection (flow temperature too high)
F.20Temperature limiter has tripped
F.20Max. temperature limiter (flow temperature too high)
F.20Software not compatible
F.20Safety shutdown: safety temperature limiter
F.20Temperature limiter has been activated
F.21System water pressure too low, Leak in the system or Expansion vessel defective
F.22System water pressure too high, Defective expansion vessel System filled to too high a pressure
F.22Safety shut-down: water shortage
F.22Dry-fire protection
F.22Dry-fire protection (no water in appliance)
F.22Boiling dry
F.22Low water protection active dry-fire protection active
F.23Low water (temperature difference between flow and return sensors too large)
F.23Low water (temperature spread too large)
F.23Low water; temperature spread between flow and return temperature sensors too large
F.23Safety shutdown: temperature spread too large
F.24Safety shutdown: temperature rise too rapid
F.24Return temperature > 90 °C, Insufficient circulation or No circulation
F.24Water shortage (temperature rising too quickly)
F.24Low water (temperature rises too quickly)
F.24Low water, temperature rise too rapid
F.24Low water protection contact closed without the pump running
F.25Wrong gas type
F.25Open circuit in wiring harness of burner, fan and gas valve
F.25Flow temperature rising too quickly. See F 05. System resistance too high, bypass insufficient
F.26Too large a temperature difference between flow and return temperature in central heating mode
F.26Gas valve stepper motor current implausible
F.26Problem with gas valve unit
F.26Modulation coil current unexplainably high
F.26Gas valve fault
F.27Incorrect ionisation measurement
F.27Ionisation signal with closed gas valves
F.27Incorrect ionisation signal
F.27Incorrect ionisation signal
F.27Safety shut-down: flame simulation
F.28The flame signal was not detected during the ignition phase
F.28Appliance does not start: ignition attempts failed during start-up
F.29Lockout during operation: re-ignition unsuccessful
F.29Ionisation protection (flame goes out during operation and subsequent ignition attempts failed)
F.29Flame extinguished during operation
F.29Flame goes out during operation and the subsequent ignition attempts failed
F.29Flames extinguish during operation and subsequent ignition attempts fail
F.30Open circuit of boiler temperature sensor
F.317Volume sensor in hot water circuit not connected/loose/defective
F.318Diverter valve motor fault
F.32Air-side frost protection (fan speed deviation)
F.32Air-side frost protection is active, no tacho signal from the fan
F.32Frost protection active
F.32Fan speed deviation
F.320Pump blocked
F.321Pump defective
F.322Pump overheated
F.323Pump running dry
F.324Cable to pump is defective
F.325Pump blocked and/or defective
F.326Diverter valve motor fault
F.327Hot water circuit clogged/blocked
F.33Air pressure switch does not switch
F.33Frost protection has responded three times and is active
F.33Air-side frost protection is active, no signal from the pressure switch
F.33Pressure switch does not switch
F.344Ionisation/control electrode fault
F.346Failed burner start
F.35Flue gas outlet/air supply fault
F.35Flue gas outlet/air supply fault
F.36TTB fault
F.36n/a
F.36Flue gas outlet recognised
F.363Display EEPROM defective
F.37Incorrect fan speed during normal operation
F.37Fan speed too high or too low during operation
F.37Speed deviation during operation
F.37Speed deviation during operation
F.38Short circuit of fan
F.38Short circuit in the fan
F.38Short circuit of fan
F.390Initialisation missing
F.40The amount of air is too low
F.40Fault in the flue gas path due to recirculation or flue gas blockage
F.41No gas-side setting (new electronics)
F.42Coding resistor error
F.43No valid appliance variant
F.44Ionisation too low
F.44Fault in the flue gas path due to recirculation or flue gas blockage
F.46Short circuit: temperature sensor at the water inlet of the solar circuit
F.47Disconnection of the hot water sensor in the cylinder outlet
F.49Voltage on EBUS too low

Order parts for your Vaillant boiler

Vaillant parts are available from Instalpunt; shipping to EU countries from €17.95 (€24.95 for more distant countries), usually 3–5 working days.

Parts by Vaillant series: ecoTEC plus · ecoTEC pro.

View Vaillant parts →

Frequently asked questions about Vaillant faults

What does a fault on a Vaillant boiler mean?

The appliance is reporting that it has shut itself down or cannot continue. The code on the display points to the group of causes: ignition, water pressure, a sensor, the fan or communication with the thermostat. The table above shows, for each code, what Vaillant means by it.

How do I reset my Vaillant boiler?

The reset button is on the control panel of your Vaillant boiler; on most appliances you hold it down for two to five seconds until the display responds. Reset once. If the same fault comes straight back, resetting will not solve it and a part or a setting needs attention. Always consult the manual for your model: the position of the button and how long to press it differ per series.

Can I fix a Vaillant fault myself?

You can top up the water pressure, bleed the system, replace filters and clean a siphon yourself. Anything behind the sealed section of a gas appliance is a different matter: work on the gas valve, burner, heat exchanger and flue must be carried out by a certified gas engineer.

How much does it cost to fix a fault?

That depends on the cause and whether a part is needed. With us you can see the part straight away with its price and delivery time, so you know where you stand in advance. If you call in an engineer, always ask about the call-out charge and hourly rate before they come.