Buderus fault code VEE601

In brief

Fault code VEE601 on a Buderus boiler (including Logamax plus GB402-320 G20 and Logamax plus GB402-320 G25) means: Flow temperature sensor measurement. Successive flow temperature measurements differ too much from one another. Reset the appliance once. If the code comes back, a part is usually faulty, often a temperature sensor. You can check the water pressure and settings yourself; leave work on gas-carrying parts to a certified gas engineer.

After a safety alert (gas, flue gas, combustion), reset no more than once and call in a certified gas engineer. If you smell gas, call your national gas emergency number or 112 immediately.

Cause

Fault code VEE601 on a Buderus boiler indicates: Flow temperature sensor measurement. Successive flow temperature measurements differ too much from one another.

Applies to

Buderus Logamax plus GB402-320 G20, Logamax plus GB402-320 G25, Logamax plus GB402-395 G20, Logamax plus GB402-395 G25, Logamax plus GB402-470 G20, Logamax plus GB402-470 G25, Logamax plus GB402-545 G20, Logamax plus GB402-545 G25, -.

Fault code VEE601 on other Buderus series

The same code does not mean the same thing on every series. Check the rating plate to see which series you have:

  • VEE601 on GB312, -: Boiler temperature sensor measurement (dual sensor).

Matching parts

Buderus parts are available from Instalpunt; shipping to EU countries from €17.95 (€24.95 for more distant countries), usually 3–5 working days.

To fix this fault you often need a replacement part. View the available Buderus parts:

All Buderus parts →

Further reading on this cause

Other Buderus codes with the same cause

  • 0Y 276 — The flow temperature sensor has measured a temperature higher than 95°C.
  • 0Y 277 — The safety temperature sensor has measured a temperature higher than 95°C.
  • 0Y 285 — The return temperature sensor has measured a temperature higher than 95°C.
  • 1C210 — The flue gas sensor has measured too high a temperature and is open.
  • 2F260 — The flow temperature sensor measures no temperature rise after a burner start.
  • 2F271 — The heating water temperature difference measured between the flow and safety temperature…

Fix it yourself or call an engineer?

Always consult the manual for your appliance and work safely. If in doubt or if the fault comes back, call in a qualified professional. A question about a part? Write to us at info@instalpunt.nl.

Frequently asked questions

What does Buderus boiler fault code VEE601 mean?

Flow temperature sensor measurement. Successive flow temperature measurements differ too much from one another.

How do I fix fault code VEE601 on a Buderus boiler?

First check the cause described above. Then restart the appliance using the reset button. If the message comes back, a part usually needs replacing or the fault needs to be repaired by a qualified professional.

Which parts do I need for Buderus fault code VEE601?

That depends on the exact cause. In the Buderus parts overview at Instalpunt you will find the current price and stock for each part.

Can I fix fault code VEE601 myself?

You can reset the appliance and check things like the water pressure or settings yourself. Work on gas-carrying parts must be left to a certified gas engineer.