Boiler fault codes

Nefit boiler faults: fault codes, causes and parts (page 3 of 5)

Codes 301 to 450 of the 619 fault codes for Nefit. Looking for a specific code? Use the search on the first page.

Nefit boiler fault codes 301 to 450 of 619

The code list is split over 5 pages. Looking for a specific code? Use the search on the first page: it searches all 619 codes in one go.

CodeCause
2F 271The measured temperature difference between the flow and safety temperature sensors is too large.
2F 271Temperature difference fault
2F 338Start test aborted too often
2F 345The flow temperature sensor measures no temperature rise after a burner start.
2F 578During the sensor test a temperature difference that is too large was measured between the flow and return temperature sensor.
2H 358The diverter valve is being unblocked.
2H 358The diverter valve is being unblocked.
2L 266The pump test has failed.
2L 266The pressure sensor has measured insufficient flow on the central heating side. This check is repeated every 5 minutes.
2L 266The sensors in the boiler measure a deviating temperature.
2L 266After four attempts the pressure sensor was unable to measure a pressure rise on the central heating side.
2L 329The pressure sensor measures no water flow
2L 329The pressure sensor measures no water flow.
2PSafety sensor temperature rising too quickly Too many radiators closed, open more radiators. Bypass is fitted too close to the boiler, fit bypass at least 6 metres from the boiler. Boiler output of the appliance is too large for the system, adjust the boiler output. The safety sensor may be faulty or worn
2PSafety sensor temperature rises too quickly
2P 212Temperature fault: The flow or safety sensor has measured a value greater than 5 K/sec.
2P 212The temperature measured by the flow temperature sensor or the safety temperature sensor rises too quickly.
2P 212The temperature measured by the flow temperature sensor or the safety temperature sensor rises too quickly.
2P 212The temperature measured by the flow temperature sensor or the safety temperature sensor rises too quickly
2P 341The sensors in the boiler measure a deviating temperature.
2P 341The temperature measured by the flow temperature sensor or the return temperature sensor rises too quickly.
2P 342The temperature measured by the flow temperature sensor rises too quickly.
2UOpen the air separator one turn (if it was closed).
2UOpen the air separator one turn (if it is closed)
2UOpen the air separator one turn (if it was closed)
2U 213Central heating water temperature difference fault
2U 213The measured temperature difference between the flow and return temperature sensors is too large.
2U 213The measured temperature difference between the flow and the return temperature sensors is too large.
2U 213The measured temperature between the flow and return temperature sensor is too large.
2U 349The temperature difference measured at low load between the flow and return temperature sensors is too large.
2U 349The temperature difference measured at low load between the flow and return temperature sensors is too large.
2U 349The temperature difference measured at low load between the flow temperature sensor and the return temperature sensor is too large.
2Y 281Water pressure fault: The pump is seized or running dry.
2Y 281The pump is seized or running dry.
2Y 282The pump control signal is missing.
2Y 282Pump fault
305Boiler temporarily unable to start after domestic hot water priority
306After gas shut-off: flame is detected
323Communication fault of the controller
328Mains supply briefly interrupted
341Appliance temperature rises too quickly
342Temperature rise in domestic hot water mode too rapid
350Short circuit of flow temperature sensor
351Open circuit of flow temperature sensor
356Supply voltage for the heat source is too low
357Venting programme
358Pump test programme active
360Incorrect coding plug
362Service coding plug recognised
363System fault in appliance electronics: fault during test of the ionisation signal
364Solenoid valve EV2 leaking
365Solenoid valve EV1 leaking
3A 264Fan tacho signal fault. The fan tacho signal was lost during the operating phase.
3A 264The control signal or the voltage of the fan has been lost during operation.
3A 264The control signal or the voltage of the fan has been lost during operation.
3CAppliance does not start, there may be an open circuit in the electrical circuit, check that the connection (pink / pink or, with the old cable colours, brown-white / pink) in the wiring harness under the UBA is not loose. Check the UBA by temporarily connecting another UBA.
3CAppliance does not start, there may be an open circuit in the electrical circuit.
3C 217The fan speed is irregular during start-up.
3C 217Air transport fault. No air transport after a set time.
3C 217The fan runs irregularly during start-up.
3F 273The boiler was switched off for a maximum of 2 minutes because the boiler has been in continuous operation for 24 hours.
3F 273The boiler has been switched off for a maximum of 2 minutes because the boiler has been in continuous operation for 24 hours. This is a safety check.
3F 273The boiler was switched off for a maximum of 2 minutes.
3F 273The appliance was switched off for a few seconds because the appliance has been in continuous operation for 24 hours.
3L 214Fan does not run during the start-up phase.
3L 214The fan does not run during the start-up phase (0C).
3L 214Tacho signal fault
3L 214The fan does not run during the start-up phase (code “0C”).
3P 216The fan is running too slowly.
3P 216Fan fault
3P 216Fan fault: The fan runs too slowly.
3P 216The fan speed is too low.
3Y 215The fan is running too fast.
3Y 215The fan speed is too high.
3Y 215Fan fault: The fan runs too fast.
3Y 215Lockout fault: The fan runs too fast.
3Y 215Lockout fault code: the fan runs too fast.
4 222The contacts of the flow temperature sensor are short-circuited.
4 222The contacts of the flow temperature sensor are short-circuited.
4AFlow sensor temperature is too high (> 101 C) The flow sensor and/or return sensor faulty, worn, contaminated. Measure the resistance of the flow sensor.
4AFlow sensor temperature is too high (> 101 °C)
4A 218The flow temperature sensor has measured a temperature higher than 105 °C.
4A 218The flow sensor has measured a central heating water temperature higher than 105 °C.
4A 332The flow temperature sensor has measured a temperature higher than 105 °C.
4A 332The flow temperature sensor has measured a temperature higher than 110 °C.
4CFuse F2 is faulty. Burner thermostat has become too hot. The flow temperature is too high Too many radiators closed, open more radiators. Bypass is fitted too close to the boiler, fit bypass at least 6 metres from the boiler.
4CFuse F2 is defective. Burner thermostat has overheated. The flow temperature is too high.
4C 224Heat exchanger limit thermostat or flue gas limit thermostat has tripped.
4C 224The safety temperature sensor has measured an excessively high temperature and is open.
4C 224The burner thermostat has measured a temperature that is too high and is open.
4C 224The limit thermostat or burner thermostat has measured a temperature that is too high and is open.
4E 278The sensor test has failed
4E 347The return temperature sensor has measured a higher central heating water temperature than the flow temperature sensor. A restart follows after 10 minutes.
4E 347The return temperature sensor has measured a higher central heating water temperature than the flow temperature sensor. A restart follows after 10 minutes.
4E 375The contacts of the external sensor (e.g. solar sensor) are short-circuited.
4E 376The contacts of the external sensor (e.g. solar sensor) are open circuit.
4FThe temperature of the safety sensor is higher than 101C There is too much resistance in the central heating circuit, the bypass is incorrectly installed or set. The safety sensor may be faulty or worn. The pump receives no voltage. Water level in the central heating circuit is too low.
4FThe temperature of the safety sensor is higher than 101 °C
4F 219The flow sensor has measured a central heating water temperature higher than 105 °C.
4F 219The safety sensor has measured a central heating water temperature higher than 105 °C.
4F 219The safety temperature sensor has measured a temperature higher than 105 °C.
4F 219The safety temperature sensor has measured a temperature higher than 105 °C.
4LThe safety sensor is short-circuited The sensor is faulty. Measure the resistance of the sensor
4LThe safety sensor is short-circuited
4L 220The contacts of the safety sensor are short-circuited or the safety sensor has measured a central heating water temperature higher than 130 °C.
4L 220The contacts of the safety sensor are short-circuited, or the safety sensor has measured a central heating water temperature higher than 130 °C.
4L 220The contacts of the safety temperature sensor are short-circuited or the safety temperature sensor has measured a temperature higher than 130 °C.
4L 220The contacts of the safety temperature sensor are short-circuited or the safety temperature sensor has measured a temperature higher than 130 °C.
4PThe safety sensor makes no contact The sensor is faulty. Measure the resistance of the sensor
4PThe safety sensor makes no contact
4P 221The contacts of the safety sensor are short-circuited or the safety sensor has measured a central heating water temperature higher than 130 °C.
4P 221The contacts of the safety sensor are short-circuited, or the safety sensor has measured a central heating water temperature higher than 130 °C.
4P 221The contacts of the safety temperature sensor are open circuit.
4UThe flow sensor is short-circuited The flow sensor and/or return sensor faulty, worn, contaminated. The safety sensor may be faulty or worn
4UThe flow sensor is short-circuited
4U 222The contacts of the flow sensor are open circuit
4U 222The contacts of the flow temperature sensor are short-circuited.
4U 350The contacts of the flow temperature sensor are short-circuited.
4U 522A sensor test is being carried out. The boiler waits until the test has passed.
4U 522A sensor test is being carried out
4YThe flow sensor makes no contact The flow sensor and/or return sensor faulty, worn, contaminated. The safety sensor may be faulty or worn.
4YThe flow sensor makes no contact
4Y 223The contacts of the flow sensor are open circuit.
4Y 223The contacts of the flow temperature sensor are open-circuit.
4Y 351The contacts of the flow temperature sensor are open circuit.
5AUBA locked out: Fault caused by use of Service Tool
5AUBA locked out Fault caused by use of Service Tool
5CUBA locked out
5C 226Service Tool has been connected.
5FService Tool: service test takes too long.
5FUBA locked out
5H 268Operating code: Component test phase.
5H 268Component test phase
5P 552A reset has been carried out more often than permitted by a controller or room thermostat connected to the boiler.
5YUBA locked out
5YService Tool: service test takes too long or a boiler parameter has been changed.
5YNefit Service Tool: service test takes too long or a boiler parameter has been changed.
604System fault in burner control unit
6ANo ionisation occurs after the ignition phase, a flame is present but the flame is lost while the fan speeds up The burner receives too little gas or there is air in the gas pipe
6ANo ionisation occurs after the ignition phase, but the glow plug/fan do work
6ANo ionisation occurs after the ignition phase, the glow plug does not work
6ANo ionisation occurs after the ignition phase, the fan is not running The fan is not working properly: check fan connectors, fuses.
6A 227The burner does not ignite
6A 227Ionisation current fault The ionisation current is too high. The indicator flashes at a frequency of 1 Hz. No central heating operation and no domestic hot water.
6A 227Insufficient ionisation current has been measured after the burner ignited.
6A 227Insufficient ionisation current measured after the burner ignited
6CIonisation occurs after the heat demand has ended, the gas valve does not close
6CIonisation occurs after the heat demand has ended, the gas valve does not close
6C 228An ionisation current was measured before the burner started.
6C 228Ionisation current fault: Ionisation current was measured after the burner went out.