Boiler with display and pressure gauge
Boiler fault codes

Viessmann boiler faults: fault codes, causes and parts (page 2 of 2)

Codes 151 to 285 of the 285 fault codes for Viessmann. Looking for a specific code? Use the search on the first page.

Viessmann boiler fault codes 151 to 285 of 285

The code list is split over 2 pages. Looking for a specific code? Use the search on the first page: it searches all 285 codes in one go.

CodeCause
95CO limit value exceeded
95OpenTherm remote control not connected
96CO monitor sensor error
98Open circuit of temperature sensor /
99Open circuit of temperature sensor aÖ
9AOpen circuit of collector temperature sensor
9BOpen circuit of collector return temperature sensor
9COpen circuit of cylinder temperature sensor
9EToo little or no flow in the solar circuit or tem- perature monitor has been activated.
9FSolar control module or Vitosolic error
ADynamic gas pressure too low, gas pressure monitor switches system off
A2System pressure too low
A3Flue gas temperature sensor not positioned correctly
A4Max. system pressure exceeded
A7Control section defective
A8Air in the internal circulation pump or minimum flow rate not reached
A9Internal circulation pump blocked
A9OpenTherm appliance communication error
B0Short circuit of flue gas temperature sensor
B1Control unit communication error
B5Internal fault
B7Boiler coding plug error
B8Open circuit of flue gas temperature sensor
BACommunication error with expansion kit for heating circuit 2 (with mixing valve)
BBCommunication error with expansion kit for heating circuit 3 (with mixing valve)
BCCommunication error with Vitotrol remote control, heating circuit 1 (without mixing valve)
BDCommunication error with Vitotrol remote control, heating circuit 2 (with mixing valve)
BECommunication error with Vitotrol remote control, heating circuit 3 (with mixing valve)
BFIncorrect LON communication module
C1Communication error with EA1 expansion
C2Communication error with solar control module or Vitosolic
C3Communication error with AM1 expansion
C4Communication error with Open Therm expansion
C5Communication error with speed-controlled internal pump
C6Communication error with speed-controlled external heating pump, heating circuit 2 (with mixing valve).
C7Communication error with speed-controlled external heating pump, heating circuit 1 (without mixing valve).
C8Communication error with speed-controlled external heating pump, heating circuit 3 (with mixing valve).
CDcommunication error
CFCommunication error with communication module
D3Communication error with fan unit
D4Air mass flow in fan unit not detected.
D5Fan blocked
D6Input DE1 on EA1 expansion reports a fault.
D7Input DE2 on EA1 expansion reports a fault.
D8Input DE3 on EA1 expansion reports a fault.
DAShort circuit in room temperature sensor, heating circuit 1 (without mixing valve)
DBShort circuit in room temperature sensor, heating circuit 2 (with mixing valve)
DCShort circuit in room temperature sensor, heating circuit 3 (with mixing valve)
DDOpen circuit in room temperature sensor, heating circuit 1 (without mixing valve)
DEOpen circuit in room temperature sensor, heating circuit 2 (with mixing valve)
DFOpen circuit in room temperature sensor, heating circuit 3 (with mixing valve)
E0Fault in external LON nodes
E1Ionisation current too high during calibration
E2No calibration due to insufficient flow rate
E3Heat draw-off too low during calibration. Temperature monitor has been switched off.
E3Fault in the safety circuit
E424 V supply voltage fault
E5Flame amplifier fault
E5Internal fault
E6System pressure too low
E7Ionisation current too low during calibration
E8Ionisation current not in the valid range
E9Repeated flame loss during calibration
EAIonisation current too low during calibration. Difference from the previous value not plausible.
EBProcess fault, shutdown during calibration.
ECParameter error during calibration
EEFlame signal is not present or too low at burner start.
EFFlame loss immediately after flame formation (during the safety time).
EdInternal fault in the control unit
FSee fault code
F 04Burner control unit has been reset more than 5 times in the last 15 min
F 11Undervoltage detection
F 12Power failure, loss of voltage detected
F 13Safety circuit not de-energised
F 16EMC fault
F 40Incorrect setting of fan setpoint in parameter set
F 41Fan defective, cable "100A" defective or open circuit, fan not suitable for the required speed
F 42Fan defective, external power supply to the fan not connected or defective, cable "100A" defective or open circuit, fan blocked (possibly by foreign object)
F 43Internal fault in the burner control unit and during test of the ionisation input
F 4FStick does not match the burner control unit
F 4bParameter set activated but stick not inserted in burner control unit; stick defective
F 4cParameters could not be transferred from the stick
F 4dPassword entered for the stick is not valid
F 50Internal fault in the actuator feedback signal, output relay does not switch
F 53 (9)Gas valve does not open, gas valve leaks
F 54EEPROM of the stick changed or erased; stick defective
F 55Stick defective
F A0 and F A1Internal fault, fan cannot reach the setpoint
F A2Open circuit, safety circuit was opened (jumper plug fJ)
F A3Values in the burner control unit and the parameter memory stick differ; time-out because the password was not entered
F A4 and F A5Internal fault in the feedback signal of the gas safety valves, output relay does not switch
F A6Gas multiblock leaks; gas escapes and burns
F A7Ionisation electrode incorrectly set, plug of the ionisation cable not connected Ignition electrodes incorrectly set Insulation sheath of the ignition electrodes cracked Incorrect gas type set Combination gas valve does not open Connections "L 1" and "N" of the mains connection of the controller or of the burner control unit swapped Combustion values not optimal
F A8Incorrect gas type set Flame cup faulty Wrong parameter memory stick inserted Combustion values not optimal
F A9Incorrect gas type Flame cup faulty Wrong parameter memory stick inserted Combustion values not optimal
F AAWind influence on fan
F AAAir pressure switch defective
F AEValve 1 leaks
F AFValve 2 leaks
F AbAir pressure switch defective, incorrectly connected or incorrectly set
F AbFlue gas blockage, condensate blockage
F AbFan defective, cables defective or open circuit
F AdGas valve closed, gas pressure switch defective
F0Internal fault
F1Flue gas temperature limiter has been activated.
F1Maximum flue gas temperature exceeded
F1 (flashing)Parameter memory stick not inserted correctly or defective
F2Temperature limiter has been activated
F2Temperature limiter has been activated.
F2 (flashing)Connected indication is invalid
F3Flame signal already present at burner start.
F3Flame signal already present at burner start
F4No flame signal.
F7Short circuit or open circuit in water pressure sensor.
F8Fuel valve or modulation valve does not close.
F8Fuel valve closes with a delay.
F8Fuel valve closes too late
F9Fan speed too low at burner start
F9Fan speed too low
FAStandstill or required fan speed not reached
FAFan standstill not reached
FBFlame loss in the stabilisation or operating phase
FCGas multiblock defective or incorrect control of modulation valve or flue gas path blocked
FCElectrical control of fan (control unit) defective
FEEEPROM error on PCB
FEBoiler coding plug missing.
FFInternal fault or reset button R is blocked
FFAutomatic burner control fault
FFBurner control unit fault
FdBurner control unit fault
FdAutomatic burner control fault
b0Short circuit of flue gas temperature sensor
b7Burner control unit fault
b8Open circuit of flue gas temperature sensor
c00Data from the new parameter memory stick transferred by password