Boiler fault codes

Baxi boiler faults: fault codes, causes and parts

All 31 fault codes for Baxi boilers, plus the faults that show no code. Type your code or choose your symptom.

In brief

A fault on a Baxi boiler usually means that the appliance has locked out or is reporting a fault code. Note the code on the display and look it up below: for each code you will find its meaning, checks you can safely do yourself and the parts that are often checked or replaced. Frequently searched: 154 (plausibility criteria not with), 20 (short circuit or open circuit of boiler…), 62 (incompatible room sensor connected). No code? Check the water pressure (1.5 to 2 bar when cold), the power supply and the gas tap, and reset once. If the fault comes back, call in a certified gas engineer. If you smell gas, call your national gas emergency number or 112 immediately.

Most searched Baxi faults

These are the codes that visitors to this site search for most often.

See the 25 most searched fault codes of 2026, with the figures behind them →

Baxi boiler faults without a code on the display

Not every fault shows a code. These are the symptoms we come across most often with Baxi appliances, with what you can check yourself before calling someone out.

No hot water, but the heating works

The boiler heats the radiators but not the tap water. Check that the hot water function is switched on in the display (on some appliances it is called DHW mode or summer mode) and that the hot water valve under the boiler is open. If the water stays cold, this usually points to a fouled or leaking DHW heat exchanger, a faulty diverter valve or a DHW sensor giving incorrect readings. View the matching parts → Read the full explanation: no hot water, six causes →

Water pressure keeps dropping

Top up to 1.5–2 bar when cold and bleed the radiators. If the pressure drops again within a few days, the expansion vessel has often lost its pre-charge or there is a small leak in the system. A pressure relief valve that keeps dripping gives the same symptom. View the matching parts → Read the full explanation: water pressure keeps dropping – expansion vessel or leak? →

Boiler shuts down and locks out

The appliance shuts down and only starts again after a reset. Reset once; if the fault comes straight back, leave the reset button alone. Repeatedly resetting a locked-out boiler is not without risk: the safety device trips for a reason. View the matching parts → Read also: is the boiler cutting out because of a sensor or overheating? →

Radiators stay cold

Check that the thermostat is calling for heat, that the radiator valves are open and that the system has enough pressure. If everything stays cold while the boiler is firing, the circulation pump is often not running or the diverter valve is stuck in the hot water position. View the matching parts → Read the full explanation: radiators stay cold →

Ticking, humming or boiling noise

A banging noise at start-up usually points to air or limescale in the heat exchanger. A humming pump may have a worn bearing. A rattling fan is often rubbing or dirty. View the matching parts → Read also: replacing the fan – what to rule out first →

Water under the boiler

Check where it is coming from: the condensate drain (siphon blocked or cracked), the pressure relief valve (pressure too high or faulty expansion vessel) or a fitting. If in doubt, switch the boiler off and close the water supply. View the matching parts → Read the full explanation: water under the boiler – condensate or a leak? →

All 31 Baxi boiler fault codes

CodeCause
10Short circuit or open circuit of outdoor sensor
100Two master clocks
105Maintenance message
110STB lockout, temperature exceeded
111STB lockout, temperature exceeded
119Low water protection lockout
132Safety lockout (e.g. due to gas pressure switch)
133Burner control unit in lockout (no flame signal after safety time elapsed)
134Loss of flame during operation
135Poor air supply
140LPB segment number or appliance number incorrect
148Incompatibility between LPB interface and base appliance
151Internal error LMU
152Error in LMU setting
153Boiler in lockout
154Plausibility criteria not with
160Threshold regime not reached
161Maximum regime exceeded
183The boiler is in setting mode
20Short circuit or open circuit of boiler flow sensor
32Short circuit or open circuit of flow sensor (CIR, CIM)
40Short circuit or open circuit of boiler return sensor
50Short circuit or open circuit of DHW sensor 1
52Short circuit or open circuit of DHW sensor 2
61Room sensor fault
62Incompatible room sensor connected
81LPB bus short circuit or no bus power supply
82LPB bus address conflict
91EPROM data loss, internal error LMU
92Electronic hardware error
95Incorrect time

Order parts for your Baxi boiler

Baxi parts are available from Instalpunt; shipping to EU countries from €12.95 (€16.95 for more distant countries), usually 3–5 working days.

View Baxi parts →

Frequently asked questions about Baxi faults

What does a fault on a Baxi boiler mean?

The appliance is reporting that it has shut itself down or cannot continue. The code on the display points to the group of causes: ignition, water pressure, a sensor, the fan or communication with the thermostat. The table above shows, for each code, what Baxi means by it.

How do I reset my Baxi boiler?

The reset button is on the control panel of your Baxi boiler; on most appliances you hold it down for two to five seconds until the display responds. Reset once. If the same fault comes straight back, resetting will not solve it and a part or a setting needs attention. Always consult the manual for your model: the position of the button and how long to press it differ per series.

Can I fix a Baxi fault myself?

You can top up the water pressure, bleed the system, replace filters and clean a siphon yourself. Anything behind the sealed section of a gas appliance is a different matter: work on the gas valve, burner, heat exchanger and flue must be carried out by a certified gas engineer.

How much does it cost to fix a fault?

That depends on the cause and whether a part is needed. With us you can see the part straight away with its price and delivery time, so you know where you stand in advance. If you call in an engineer, always ask about the call-out charge and hourly rate before they come.

Where can I find the right part for my Baxi?

Check the rating plate for the exact type and use it to search our catalogue, or search directly by the manufacturer number of the faulty part. Each part lists the appliances it fits.