Boiler with display and pressure gauge
Boiler fault codes

Bosch boiler faults: fault codes, causes and parts

All 377 fault codes for Bosch boilers, plus the faults that show no code. Type your code or choose your symptom.

In brief

A fault on a Bosch boiler usually means that the appliance has locked out or is reporting a fault code. Note the code on the display and look it up below: for each code you will find its meaning, checks you can safely do yourself and the parts that are often checked or replaced. Frequently searched: EA (flame not detected (no ionisation)), --353 (the boiler is waiting), CC (outdoor temperature). No code? Check the water pressure (1.5 to 2 bar when cold), the power supply and the gas tap, and reset once. If the fault comes back, call in a certified gas engineer. If you smell gas, call your national gas emergency number or 112 immediately.

Most searched Bosch faults

These are the codes that visitors to this site search for most often.

See the 25 most searched fault codes of 2026, with the figures behind them →

Bosch boiler faults without a code on the display

Not every fault shows a code. These are the symptoms we come across most often with Bosch appliances, with what you can check yourself before calling someone out.

No hot water, but the heating works

The boiler heats the radiators but not the tap water. Check that the hot water function is switched on in the display (on some appliances it is called DHW mode or summer mode) and that the hot water valve under the boiler is open. If the water stays cold, this usually points to a fouled or leaking DHW heat exchanger, a faulty diverter valve or a DHW sensor giving incorrect readings. View the matching parts → Read the full explanation: no hot water, six causes →

Water pressure keeps dropping

Top up to 1.5–2 bar when cold and bleed the radiators. If the pressure drops again within a few days, the expansion vessel has often lost its pre-charge or there is a small leak in the system. A pressure relief valve that keeps dripping gives the same symptom. View the matching parts → Read the full explanation: water pressure keeps dropping – expansion vessel or leak? →

Boiler shuts down and locks out

The appliance shuts down and only starts again after a reset. Reset once; if the fault comes straight back, leave the reset button alone. Repeatedly resetting a locked-out boiler is not without risk: the safety device trips for a reason. View the matching parts → Read also: is the boiler cutting out because of a sensor or overheating? →

Radiators stay cold

Check that the thermostat is calling for heat, that the radiator valves are open and that the system has enough pressure. If everything stays cold while the boiler is firing, the circulation pump is often not running or the diverter valve is stuck in the hot water position. View the matching parts → Read the full explanation: radiators stay cold →

Ticking, humming or boiling noise

A banging noise at start-up usually points to air or limescale in the heat exchanger. A humming pump may have a worn bearing. A rattling fan is often rubbing or dirty. View the matching parts → Read also: replacing the fan – what to rule out first →

Water under the boiler

Check where it is coming from: the condensate drain (siphon blocked or cracked), the pressure relief valve (pressure too high or faulty expansion vessel) or a fitting. If in doubt, switch the boiler off and close the water supply. View the matching parts → Read the full explanation: water under the boiler – condensate or a leak? →

Bosch boiler fault codes 1 to 150 of 377

The code list is split over 3 pages. Looking for a specific code? Use the search at the top of this page: it searches all 377 codes in one go.

CodeCause
"-II-"Trap filling programme in operation, see installation manual p. 43 if required.
--Service Tool: service test takes too long or a boiler parameter has been changed.
--200The boiler is in heating mode.
--201The boiler is in hot water mode.
--202The boiler is waiting. There has been a heat demand from an on/off or modulating control more than once per 10 minutes.
--203The boiler is in standby.
--204The boiler is waiting. The measured flow temperature is higher than the calculated or set central heating water temperature.
--204The boiler is waiting. The measured flow temperature is higher than the calculated or set heating water temperature.
--208The boiler is in chimney sweep mode or service mode.
--226Service Tool has been connected.
--265The boiler is waiting. The boiler regularly switches to low load to meet the heat demand.
--268Service Tool: component test phase.
--270The boiler is starting up.
--283The boiler is preparing for a burner start. The fan and the pump are activated.
--284The gas valve is activated.
--305The boiler is waiting after the end of hot water mode
--341The temperature measured by the flow temperature sensor or the return temperature sensor rises too quickly.
--353The boiler is waiting. The boiler has never been off for longer than 20 minutes within 24 hours.
-II-Trap filling programme active (see manual page 44).
00Venting function, see installation manual p. 42 if required.
1010 ONo communication via EMS BUS connection
1013 WMaximum burner hours reached
1017 WWater pressure too low
1018 WService interval elapsed
1019 WWrong pump type detected
1022 WStorage cylinder temperature sensor defective or contact problems
1023Maximum operating time including standby time reached
1023Maximum operating time including standby time reached
1025 WReturn temperature sensor defective
1037 WOutdoor temperature sensor defective, substitute mode heating active
1065 WWater pressure sensor defective or not connected
1068 WOutdoor temperature sensor or lambda sensor defective.
1070The next service is due on <dd.mm.yyyy>. Contact your installer.
1071Next service is due now. Contact your installer: <tel. no.>
1072The service is overdue. Contact your installer.
1074No signal from flow temperature sensor
1075 WShort circuit of heat exchanger temperature sensor
1076 WNo signal from heat exchanger temperature sensor
200 OHeat source in heating mode
201 OHeat source in DHW mode
202 OAppliance in switching optimisation programme
203 OAppliance ready for operation, no heat demand present
204 OActual heating water temperature of the heat source higher than setpoint
208 OHeat demand due to flue gas test
2085 VInternal fault
214 VFan is switched off during safety time
224 VSafety temperature limiter activated
227 VNo flame signal after ignition
228 VFlame signal although no flame present
229 BFlame lost during burner operation
232 BHeat source locked out by external switching contact
233 VBoiler identification module or appliance electronics fault
234 VElectrical fault in gas valve
235 VVersion conflict between appliance electronics / boiler identification module
237 VInstallation fault
238 VAppliance electronics defective
242-263 VInstallation fault in appliance electronics / control panel
265 OHeat demand lower than energy supplied
268 OComponent test activated
269 VFlame monitoring
273 BOperation interrupted after 24 hours of continuous operation
281 BHeating pump blocked or air in heating pump
2908 VInstallation fault in appliance electronics / control panel
2910 VFault in flue gas system
2914-2916 VInstallation fault in appliance electronics
2920 VFlame monitoring fault
2923- 2926 VInstallation fault in appliance electronics
2927 BNo flame detected after ignition
2928 VInternal fault
2931 VInstallation fault in appliance electronics / control panel
2940 VInstallation fault in burner control unit
2946 VWrong coding plug detected
2948 BNo flame signal at low output
2949 BNo flame signal at high output
2950 BNo flame signal after start procedure
2951 VToo many flame interruptions
2952 VInternal fault when testing the ionisation signal
2955 BSet parameters for the hydraulic configuration are not supported by the heat source.
2956 OHydraulic configuration on heat source is activated
2957 VInstallation fault in appliance electronics
2961-2962 VNo ventilation signal present
2963 BSignal on flow and heat exchanger temperature sensor outside permitted range
2964Volume flow in heat exchanger too low
2965 BFlow temperature too high
2966 BFlow temperature in heat exchanger rises too quickly
2967Temperature difference between flow / heat exchanger temperature sensors too large
2968Heating water is being topped up
2970Pressure loss in heating system too rapid
2971 BOperating pressure too low
2972Mains voltage too low
2P564Temperature sensor temperature rise too fast ( > 70 K/min).
2P564Temperature sensor temperature rise too fast ( >70K/min).
306 VFlame signal after fuel supply closed
3071No communication with remote control
316 VFlue gas temperature too high during sensor test
317 VShort circuit of flue gas temperature sensor
318 VOpen circuit of flue gas temperature sensor
349 BDifference between flow and return temperature too large
357 OVenting programme
358 OPump test programme active
360 VInstallation fault in appliance electronics / control panel
362 VBoiler identification module or appliance electronics fault
363 VInstallation fault in appliance electronics / control panel
811 AHot water production: thermal disinfection failed
815 WTemperature sensor open diverter defective
8C373The burner thermostat has measured too high a temperature more often than permitted.
8C374Insufficient ionisation current has been measured during burning more often than permitted.
8Y572The control unit is externally locked out via the EV connector.
9A235The KIM is too new for the burner control unit.
9U233The burner control unit or the KIM is defective.
<>Heating function is interrupted for two minutes. Impermissibly rapid rise in flow temperature.
<>Impermissibly rapid rise in flow temperature.
A2Flue gases are escaping from the combustion chamber.
A2Escape of flue gas from the combustion chamber.
A2, C3Flue gases are escaping from the combustion chamber.
A3The flue gas safety device on the draught diverter has an open circuit or short circuit.
A3Flue gas safety device on the draught diverter is open-circuit or short-circuited.
A3The flue gas safety device on the draught diverter has an open circuit or short circuit.
A3317The contacts of the flue gas sensor are short-circuited.
A4The flue gas safety device TTB is activated and the burner stops 1.5 min after the start.
A4Flue gases are escaping from the draught diverter.
A4Escape of flue gas from the draught diverter.
A5Temperature sensor 2 of storage system defective.
A5Cylinder NTC 2 defective (HRC.. with storage system).
A6The flue gas safety device on the combustion chamber has an open circuit or short circuit.
A6The flue gas safety device on the combustion chamber has an open circuit or short circuit.
A6Flue gas safety device on the combustion chamber is open-circuit or short-circuited.
A7Hot water sensor has an open circuit or short circuit.
A7DHW NTC defective (only for ZWB ...).
A7DHW NTC defective (ZWN).
A7DHW NTC defective (ZWE).
A7Domestic hot water temperature sensor defective.
A7DHW NTC defective (HRC...).
A8CAN communication interrupted.
A8Communication interrupted.
A8CAN communication interrupted
A9DHW NTC not fitted correctly (on boiler ZWN ...).
AAOn boilers ZWN during hot water draw-off. Plate heat exchanger is scaled up.
AAOnly during hot water draw-off. Plate heat exchanger is scaled up.
ACNo electrical connection between plug-in module and Heatronic.
ACModule not recognised.
ACModule not recognised
AdCylinder NTC 1 is not recognised.
AdDomestic hot water NTC fault.
AdCylinder temperature sensor 1 defective.
AdCylinder NTC not recognised. The cylinder NTC was first recognised on the Heatronic 3 as a bus device and then connected to IPM 1 or IPM 2.
AdCylinder sensor not recognised.
B1Coding plug not recognised.
B2E207The water pressure is <0.8 bar
B2E207The water pressure is < 0.8 bar

Order parts for your Bosch boiler

Bosch parts are available from Instalpunt; shipping to EU countries from €17.95 (€24.95 for more distant countries), usually 3–5 working days.

View Bosch parts →

Frequently asked questions about Bosch faults

What does a fault on a Bosch boiler mean?

The appliance is reporting that it has shut itself down or cannot continue. The code on the display points to the group of causes: ignition, water pressure, a sensor, the fan or communication with the thermostat. The table above shows, for each code, what Bosch means by it.

How do I reset my Bosch boiler?

The reset button is on the control panel of your Bosch boiler; on most appliances you hold it down for two to five seconds until the display responds. Reset once. If the same fault comes straight back, resetting will not solve it and a part or a setting needs attention. Always consult the manual for your model: the position of the button and how long to press it differ per series.

Can I fix a Bosch fault myself?

You can top up the water pressure, bleed the system, replace filters and clean a siphon yourself. Anything behind the sealed section of a gas appliance is a different matter: work on the gas valve, burner, heat exchanger and flue must be carried out by a certified gas engineer.

How much does it cost to fix a fault?

That depends on the cause and whether a part is needed. With us you can see the part straight away with its price and delivery time, so you know where you stand in advance. If you call in an engineer, always ask about the call-out charge and hourly rate before they come.

Where can I find the right part for my Bosch?

Check the rating plate for the exact type and use it to search our catalogue, or search directly by the manufacturer number of the faulty part. Each part lists the appliances it fits.