Boiler with display and pressure gauge
Boiler fault codes

Bosch boiler faults: fault codes, causes and parts (page 3 of 3)

Codes 301 to 377 of the 377 fault codes for Bosch. Looking for a specific code? Use the search on the first page.

Bosch boiler fault codes 301 to 377 of 377

The code list is split over 3 pages. Looking for a specific code? Use the search on the first page: it searches all 377 codes in one go.

CodeCause
V or B8L534No gas supply pressure. Flue gas pressure limiter is activated. Air pressure switch is activated. Air pressure switch is defective.
V or B8L534Insufficient gas supply pressure. Flue gas pressure limiter is activated. Air pressure switch is activated. Air pressure switch is defective.
V2U533Boiler or pump hydraulically connected incorrectly
V2U575Flow ISTB (intelligent safety temperature limiter)
V3C537No speed
V3C538Fan speed too low
V3C540Fan speed too high
V4A520Flow ISTB (intelligent safety temperature limiter)
V4A575Activation of the ISTB (intelligent safety temperature limiter)
V4A700Factory default state
V4U521Sensor difference between temperature sensors 1 and 2 too large.
V4U521Sensor difference between temperature sensors 1 and 2 too large.
V4U522Temperature sensor short circuit between temperature sensors 1 and 2.
V4U524Temperature sensor short circuit
V4Y523Boiler temperature sensor open circuit
V6A578No flame within the safety time
V6C576Ionisation current during pre-purge >0.9μA.
V6C576Ionisation current during pre-purge > 0.9 μA
V6L5615 times "Power up" (power interruption during the burner start).
V6L5615 times "Power up" (power interruption during the burner start)
V8P580Solenoid valve 1 leaking
V8U581Solenoid valve 2 leaking
V9Y500 501 502 503Internal fault of burner control unit relay
V9Y500, 501, 502, 503Internal fault of burner control unit relay
VA01800Outdoor temperature sensor is defective
VA01808DHW temperature sensor 1 defective. If necessary, deactivate the hot water function
VA01808DHW temperature sensor 1 defective. If necessary, deactivate the hot water function.
VA01810Hot water stays cold
VA01845Hydraulic configuration is not supported
VAD1818Heat generator stays cold
VCO568Water pressure sensor fault (cable break)
VCO569Water pressure sensor fault (short circuit)
VCY566Return temperature < 5 °C (open circuit)
VCY566Return temperature <5°C (open circuit)
VCY567Return temperature >130°C (short circuit)
VCY567Return temperature > 130 °C (short circuit)
VCY573Flow temperature < 5 °C (open circuit)
VCY573Flow temperature <5°C (open circuit)
VCY574Flow temperature >130°C (short circuit)
VCY574Flow temperature > 130 °C (short circuit)
VEE601Temperature sensor measurement (dual sensor)
VEE612Return temperature sensor measurement
VEE613Flow temperature sensor measurement
VLL571Too many restarts despite reset
VLP570Too many resets via the interface
b1Coding plug not recognised.
b1Coding plug.
b2, b3Internal data error.
b2/b3/ b4/b5/b6Internal data error.
b2/b3/b4/b5/b6Internal data error.
b7257The burner control unit or the KIM is defective.
d1Return temperature sensor defective.
d1LSM in lockout.
d1No feedback voltage from LSM.
d1240The contacts of the return temperature sensor are short-circuited.
d1241The contacts of the return temperature sensor are open-circuit.
d1242The burner control unit or the KIM is defective.
d1243The burner control unit or the KIM is defective.
d1244The burner control unit or the KIM is defective.
d1245The burner control unit or the KIM is defective.
d1247The burner control unit or the KIM is defective.
d1248The burner control unit or the KIM is defective.
d1249The burner control unit or the KIM is defective.
d1255The burner control unit or the KIM is defective.
d3Temperature limiter TB1 defective. External limiter has tripped. Temperature limiter in lockout.
d3Temperature limiter TB 1 defective. External temperature limiter has switched off. Temperature limiter in lockout.
d3Jumper 8-9 not recognised.
d3Temperature limiter TB 1 defective. External temperature limiter has switched off. Temperature limiter is in lockout.
d3232The external switching contact is open.
d4213The temperature measured by the flow temperature sensor or the return temperature sensor rises too quickly.
d4286The return temperature sensor has measured a heating return temperature higher than 105 °C.
d4342The temperature measured by the flow temperature sensor rises too quickly.
d5External flow temperature sensor defective (open diverter). External flow temperature sensor was recognised as a bus device and then connected differently.
d5External temperature limiter defective (low loss header). External flow sensor was recognised as a bus device, disconnected and connected at a different location.
d7Gas valve defective or modulation cable not connected.
dPGradient limitation: temperature rise too rapid.
rEA reset of the boiler is being carried out.

Bosch parts are available from Instalpunt. Back to the first page with the most searched codes and frequently asked questions.