Cv-ketel met display en manometer
CV-ketel storingscodes

ATAG CV-ketel storing: codes, oorzaken en onderdelen

Alle 234 storingscodes van ATAG cv-ketels, plus de klachten die géén code geven. Typ je code of kies je klacht.

Kort antwoord

Een storing op een ATAG cv-ketel betekent meestal dat het toestel is vergrendeld of een foutcode meldt. Noteer de code op het display en zoek hem hieronder op: per code vind je de betekenis, controles die je veilig zelf kunt doen en onderdelen die vaak gecontroleerd of vervangen worden. Vaak gezocht: C1 18 (pressure too low (), C1 33 (no flame after 5 ignition attempts), 140* (dynamic pressure increase failed 2x (no pump…). Geen code? Controleer de waterdruk (1,5 tot 2 bar in koude toestand), de stroom en de gaskraan en reset één keer. Keert de storing terug of ruik je gas: stop en bel een erkend installateur.

Meest opgezochte ATAG-storingen

Dit zijn de codes waar bezoekers van deze site het vaakst op zoeken.

Bekijk de 25 meest gezochte storingscodes van 2026, met de cijfers erachter →

ATAG cv-ketel storing zonder code op het display

Niet elke storing geeft een code. Dit zijn de klachten die wij het vaakst tegenkomen bij ATAG, met wat je zelf kunt nagaan voordat je iemand laat komen.

Geen warm water, verwarming werkt wel

De ketel maakt wel warmte voor de radiatoren maar niet voor de kraan. Kijk of de warmwaterfunctie op het display aan staat (bij sommige toestellen heet dat tapwaterbedrijf of zomerstand) en of de warmwaterkraan onder de ketel open staat. Blijft het koud, dan wijst dat meestal op een vervuilde of lekkende tapwaterwisselaar, een defecte driewegklep of een tapwatersensor die verkeerd meet. Bekijk de bijbehorende onderdelen → Lees de volledige uitleg: geen warm water, zes oorzaken →

Waterdruk valt steeds terug

Vul bij tot 1,5 à 2 bar in koude toestand en ontlucht de radiatoren. Zakt de druk binnen enkele dagen opnieuw, dan is het expansievat vaak zijn voordruk kwijt of zit er een klein lek in de installatie. Een overstortventiel dat blijft doorlopen geeft hetzelfde beeld. Bekijk de bijbehorende onderdelen → Lees de volledige uitleg: waterdruk zakt steeds, expansievat of lek →

Ketel slaat af en vergrendelt

Het toestel valt uit en start pas na een reset weer op. Reset één keer; komt de storing direct terug, blijf dan van de resetknop af. Herhaald resetten van een vergrendelde ketel is niet zonder risico: er is een reden dat de beveiliging ingrijpt. Bekijk de bijbehorende onderdelen → Lees ook: valt de ketel uit door een sensor of door oververhitting? →

Radiators stay cold

Controleer of de thermostaat warmte vraagt, of de radiatorkranen open staan en of de installatie voldoende druk heeft. Blijft alles koud terwijl de ketel wel brandt, dan draait de circulatiepomp vaak niet of staat de driewegklep in de warmwaterstand vast. Bekijk de bijbehorende onderdelen → Lees de volledige uitleg: radiatoren blijven koud →

Tikkend, brommend of kokend geluid

Een bonkend geluid bij het opstarten wijst meestal op lucht of kalk in de warmtewisselaar. Een brommende pomp kan een versleten lager hebben. Een ventilator die rateltelt loopt vaak aan of is vervuild. Bekijk de bijbehorende onderdelen → Lees ook: ventilator vervangen, wat je eerst uitsluit →

Water onder de ketel

Kijk waar het vandaan komt: uit de condensafvoer (sifon verstopt of gescheurd), uit het overstortventiel (te hoge druk of defect vat) of uit een koppeling. Zet bij twijfel de ketel uit en sluit de watertoevoer. Bekijk de bijbehorende onderdelen → Lees de volledige uitleg: water onder de ketel, condens of lek? →

ATAG cv-ketel storingscodes 1 tot 150 van 234

De codelijst is verdeeld over 2 pagina’s. Zoek je een specifieke code, gebruik dan de zoeker bovenaan deze pagina: die doorzoekt alle 234 codes in één keer.

CodeCause
10Outdoor sensor fault (e.g. open, short-circuited, out of range)
101Maximum temperature exceeded
101Overheating
102Pressure sensor fault
102Pressure sensor defective
104No pump kick
104Insufficient flow rate
105No fault; air purge programme active (approx. 7 minutes)
108Pressure < Pmin (< 0.7 bar), system must be topped up
108Pressure too low (<0.7 bar) or pump pressure increase too low (no pump detection)
109Pressure too high (>3 bar) or pump pressure increase too high
109Pressure too high (>Pmax)
110Flow sensor fault (e.g. open, short-circuited, out of range)
110Safety temperature exceeded
110Flow sensor fault (e.g. open, short-circuited, out of range)
111Maximum temperature exceeded
112Return sensor fault (e.g. open, short-circuited, out of range)
112Return sensor fault (e.g. open, short-circuited, out of range)
114Outdoor sensor fault (e.g. open, short-circuited, out of range)
114Outdoor sensor fault (e.g. open, short-circuited, out of range)
117Pressure too high (>3 bar) or pump pressure increase too high
118Pressure too low (<0.7 bar) or pump pressure increase too low (no pump detection)
119Link between positions 4 and 5 of X2 missing/open circuit
129Fan fault (fan does not start)
133No flame after 5 ignition attempts
140*Dynamic pressure increase failed 2x (no pump detection)
151Fan fault (speed control not achieved or out of range) or defective control unit.
154Flow temperature rising too quickly, dT too large, return > flow
180No fault: briefly displayed when exiting chimney sweep function
181No fault: briefly displayed when exiting 'accelerator pedal function'
197Link at 'external safety contact' position missing/open circuit
1P4Pressure < Pmin (0.7 - 1.0 bar), system must be topped up
1P4Pressure between 0.7 and 1 bar, top up to above 1.3 bar
1P9Dynamic pressure increase failed 1x
20Coding plug not recognised.
20Internal data fault
20Flow temperature sensor defective
20Domestic hot water temperature sensor incorrectly fitted
20Gas valve assembly defective
20Temperature monitor TB1 faulty External monitor has tripped. Temperature monitor locked out.
20Outdoor temperature sensor not recognised.
201Domestic hot water sensor defective (Combi)
201Domestic hot water sensor fault (e.g. open, short-circuited, out of range)
203Cylinder sensor - open circuit (Solo)
303PCB fault
303Control unit fault
304Too many resets (5x in 15 minutes)
304Too many resets
40Temperature exceeded at the burner flow temperature sensor.
40Open circuit or short circuit of the burner flow temperature sensor.
40Internal fault
40Internal data fault
40Boiler block temperature limiter has been activated
40Flame is detected although the appliance is switched off
40Flame is not detected
50Domestic hot water sensor fault (e.g. open, short-circuited, out of range)
50Gradient limitation: temperature rising too quickly
50After gas shut-off: flame is detected.
50Reset button was pressed accidentally.
501No flame detected
501Ionisation fault
61No communication via Zbus
612Fan fault (fan does not start)
78Water pressure sensor out of range or not connected or, if water pressure OK: pump defective.
B0Flow water temperature rising too quickly
B0Flow water temperature rising too quickly No or insufficient flow in the system?
B1Temperature difference between flow and return too large Insufficient flow or pump faulty?
B1Temperature difference between flow and return too large
B3Maximum flue gas temperature exceeded (if flue gas sensor fitted)
B3Maximum flue gas temperature exceeded (if flue gas sensor fitted) Blockage in the flue gas outlet?
B4Maximum flow water temperature exceeded No flow or too much resistance in the system?
B4Maximum flow water temperature exceeded
B5Maximum flow water temperature exceeded
B5Maximum return water temperature exceeded No flow or too much resistance in the system?
B6Return temperature higher than flow temperature Circulation pump fitted the wrong way round?
B6Maximum flow water temperature exceeded
B7General lockout input open
B7General lockout input open Water pressure too low or low water pressure protection faulty?
BL 01External safety contact open
BL 01External safety contact open. External safety contact (pos. 24 and 25) is active
BL 11Maximum Delta-T of flow and return sensor on central heating (CH) repeatedly exceeded Domestic hot water operation is still possible as normal during the lockout. During the lockout the pump continues to run at minimum capacity
BL 11Maximum temperature difference of flow and return sensor on CH repeatedly exceeded. Domestic hot water operation is normally possible during the lockout (LO). During the LO the pump continues to run at minimum capacity
BL 11Maximum temperature difference of flow and return sensor on CH repeatedly exceeded. Domestic hot water operation is normally possible during the lockout (LO). During the LO the pump continues to run at minimum capacity.
BL 11Maximum temperature difference of flow and return sensor on CH repeatedly exceeded. Domestic hot water operation is normally possible during the lockout (LO). During the LO the pump continues to run at minimum capacity.
BL 11Maximum temperature difference of flow and return sensor on CH repeatedly exceeded.
BL 12Maximum Delta-T of flow and return sensor on domestic hot water (DHW) repeatedly exceeded Central heating system operation is still possible as normal during the lockout. During the lockout the pump continues to run at minimum capacity.
BL 12Maximum temperature difference of flow and return sensor on DHW repeatedly exceeded. CH operation is normally possible during the lockout (LO). During the LO the pump continues to run at minimum capacity
BL 12Maximum temperature difference of flow and return sensor on DHW repeatedly exceeded. CH operation is normally possible during the lockout (LO). During the LO the pump continues to run at minimum capacity.
BL 60Incorrect parameter setting of the minimum or maximum output
BL 67A Delta-T has been detected between flow and return sensor while the burner is not operating Once the Delta-T has disappeared the lockout will be cleared
BL 67A temperature difference has been detected between flow and return sensor while the burner is not operating. Once the temperature difference has disappeared, the lockout (LO) will be cleared
BL 67A temperature difference has been detected between flow and return sensor while the burner is not operating. Once the temperature difference has disappeared, the lockout (LO) will be cleared.
BL 80Maximum flue gas temperature exceeded (if flue gas sensor fitted) The lockout (BL) is only cleared once the flue gas temperature falls below the maximum flue gas temperature
BL 80Maximum flue gas temperature exceeded (if flue gas sensor fitted) The lockout is only cleared once the flue gas temperature falls below the maximum flue gas temperature
BL 80Maximum flue gas temperature exceeded (if flue gas sensor fitted). The lockout (LO) is only cleared once the flue gas temperature falls below the maximum flue gas temperature.
BL 80Maximum flue gas temperature exceeded (if flue gas sensor fitted). The lockout (LO) is only cleared once the flue gas temperature falls below the maximum flue gas temperature.
BL 80Maximum flue gas temperature exceeded (if flue gas sensor fitted) The lockout is only cleared once the flue gas temperature falls below the maximum flue gas temperature
BL 81Flue gas sensor open circuit after having previously been connected to the controller Burner is locked out until the flue gas sensor is reconnected
BL 81Flue gas sensor open circuit after having previously been connected to the controller Burner is locked out until the flue gas sensor is reconnected
BL 81Flue gas sensor open circuit after having been connected to the controller. Burner is locked out until the flue gas sensor is reconnected.
BL 82Flue gas sensor short-circuited, heat demand blocked and pump capacity at minimum
BL 84Flue gas sensor short-circuited, heat demand blocked and pump capacity at minimum
BL 85The controller has detected no water flow. Automatic air purge cycle is started. If water flow is detected during this cycle, the air purge cycle is ended and the burner is enabled.
BL 85The controller has detected no water flow Automatic venting cycle is started. If water flow is detected during this cycle, the venting cycle is ended and the burner is enabled.
BL 85The controller has detected no water flow
BL 85The controller has detected no water flow. Automatic air purge cycle is started.
BL 86Mains frequency deviates by more than 2.5 Hz the mains frequency deviates by more than 2.5 Hz from the standard 50 Hz (<47.5 Hz, >52.5 Hz)
BL 86Mains frequency deviates by more than 2.5 Hz from the standard 50 Hz (<47.5 Hz and > 52.5 Hz)
Bx01sc01Fan is not running at the correct speed
Bx03sc01Flow sensor T1 open.
Bx03sc02Flow temperature T1 too high.
Bx05sc01Return sensor T2 open.
Bx05sc02Return temperature T2 too high.
Bx08sc01Safety contact open.
Bx12sc01Water pressure sensor open.
Bx12sc02Water pressure sensor short-circuited.
Bx12sc03Water pressure lower than 0.7 bar. Top up.
Bx12sc04Water pressure too high. Reduce pressure.
Bx12sc05No pressure increase at pump start.
Bx13sc01Temperature difference between T1 and T2 too high.
Bx15sc01Communication error between boilers.
C 10Outdoor sensor fault (e.g. open, short-circuited, out of range)
C 20flow sensor fault (e.g. open, short-circuited, out of range)
C 20Flow sensor fault
C 20Flow sensor fault (e.g. open, short-circuited, out of range)
C 20Flow sensor fault e.g. open, short-circuited, out of range.
C 40return sensor fault (e.g. open, short-circuited, out of range)
C 40Return sensor fault
C 50Domestic hot water sensor fault (e.g. open, short-circuited, out of range)
C 50Wiring fault.
C 61No communication via Z-bus (reset only possible by interrupting the power supply)
C 61OpenTherm room thermostat fault.
C 62Unknown OpenTherm room thermostat.
C 78Water pressure sensor fault
C 78Water pressure sensor out of range or not connected or, if water pressure OK: pump defective
C 78Water pressure sensor out of range or not connected or, if water pressure OK: pump defective.
C1 05Air purge programme active
C1 05Air purge programme active
C1 10safety temperature exceeded
C1 11maximum temperature exceeded
C1 17Water pressure too high (>3 bar)
C1 17pressure too high (>3 bar) or pump pressure increase too high
C1 18Pressure too low (<0.7 bar) or pump pressure increase too low (no pump detection)
C1 18Water pressure too low (<1.0 bar or <0.7 bar)
C1 29Fan fault, fan does not start
C1 29fan fault (fan does not start)
C1 33no flame after 5 ignition attempts
C1 51Fan fault (speed control not achieved or out of range)
C1 52Outdoor sensor setting incorrect. Parameter 555 b0 and/or b1 is incorrectly set to 'on'
C1 54Flow rising too quickly, delta T too large, return > flow

Onderdelen voor je ATAG cv-ketel bestellen

Onderdelen voor ATAG koop je bij Instalpunt, snel geleverd.

Onderdelen per Atag-serie: A Series · i Series (iCon) · Q Series · E Series · P-serie (iCon) · Blauwe Engel · XL-serie.

Bekijk ATAG-onderdelen →

Veelgestelde vragen over ATAG-storingen

Wat betekent een storing bij een ATAG cv-ketel?

Het toestel meldt dat het zichzelf heeft uitgeschakeld of niet verder kan. De code op het display wijst naar de oorzaakgroep: ontsteking, waterdruk, een sensor, de ventilator of de communicatie met de thermostaat. In de tabel hierboven staat per code wat ATAG ermee bedoelt.

Hoe reset ik mijn ATAG cv-ketel?

De resetknop zit op het bedieningspaneel van je ATAG cv-ketel; bij de meeste toestellen houd je hem twee tot vijf seconden ingedrukt tot het display reageert. Reset één keer. Komt dezelfde storing meteen terug, dan lost resetten niets op en is er een onderdeel of een instelling die aandacht nodig heeft. Raadpleeg altijd de handleiding van jouw type: de plaats van de knop en de duur verschillen per serie.

Kan ik een ATAG-storing zelf verhelpen?

Waterdruk bijvullen, ontluchten, filters vervangen en een sifon schoonmaken kun je zelf. Alles achter het gesloten deel van een gastoestel niet: werk aan gasblok, brander, warmtewisselaar en rookgasafvoer mag in Nederland sinds 2023 alleen door een bedrijf met CO-certificering.

Wat kost het verhelpen van een storing?

Dat hangt af van de oorzaak en of er een onderdeel nodig is. Het onderdeel zelf zie je bij ons direct met prijs en levertijd, zodat je vooraf weet waar je aan toe bent. Vraag bij een monteur altijd naar voorrijkosten en uurtarief voordat hij komt.

Waar vind ik het juiste onderdeel voor mijn ATAG?

Kijk op het typeplaatje voor het exacte type en zoek daarmee in onze catalogus, of zoek direct op het fabrikantnummer van het defecte onderdeel. Bij elk onderdeel staat op welke toestellen het past.