Vaillant fault code F.73

In brief

Fault code F.73 on a Vaillant boiler (including Hrpro and ecoCOMPACT) means: Pressure sensor open circuit. Pressure sensor wiring harness interrupted. Pressure sensor defective. Reset the appliance once. If the code comes back, a part is usually faulty, often a temperature sensor. You can check the water pressure and settings yourself; leave work on gas-carrying parts to a certified gas engineer.

After a safety alert (gas, flue gas, combustion), reset no more than once and call in a certified gas engineer. If you smell gas, call your national gas emergency number or 112 immediately.

Cause

Fault code F.73 on a Vaillant boiler indicates: Pressure sensor open circuit. Pressure sensor wiring harness interrupted. Pressure sensor defective.

Applies to

Vaillant Hrpro, ecoCOMPACT, ecoFIT pro, ecoTEC classic, ecoTEC exclusive, ecoTEC plus, ecoTEC pro classic, ecoTEC pure, CW 4/3, CW 4/4, CW 4/4 EXP, VC 1006/5-5 R3, VC 1206/5-5 R3, VC 806/5-5 R3, VHR 10 S, VHR 18 S.

Fault code F.73 on other Vaillant series

The same code does not mean the same thing on every series. Check the rating plate to see which series you have:

  • F.73 on ThermoCompact, VC 254/4-7, VCW 254/4-7, VCW 255/4-7, VCW 255/4-7 R3, VCW 255/4-7 R4: Water pressure sensor fault.
  • F.73 on Hrpro, CW 3/3, CW 4/3 EXP: Water pressure sensor error.
  • F.73 on hrSOLIDE plus, VHR 24-28/3-5: Water pressure sensor signal in the wrong range (too low).

Matching parts

Vaillant parts are available from Instalpunt; shipping to EU countries from €17.95 (€24.95 for more distant countries), usually 3–5 working days.

Parts by Vaillant series: ecoTEC plus · ecoTEC pro.

Based on the cause, these original Vaillant parts fit (always check the type number of your appliance):

All Vaillant parts →

Further reading on this cause

Other Vaillant codes with the same cause

  • F.00 — Open circuit of flow temperature sensor
  • F.01 — Open circuit of return temperature sensor (NTC)
  • F.02 — Open circuit of DHW outlet sensor
  • F.03 — Open circuit of cylinder temperature sensor/domestic hot water temperature sensor
  • F.05 — Open circuit in outdoor temperature sensor
  • F.06 — Open circuit of inside flue gas sensor

Fix it yourself or call an engineer?

Always consult the manual for your appliance and work safely. If in doubt or if the fault comes back, call in a qualified professional. A question about a part? Write to us at info@instalpunt.nl.

Frequently asked questions

What does Vaillant boiler fault code F.73 mean?

Pressure sensor open circuit. Pressure sensor wiring harness interrupted. Pressure sensor defective.

How do I fix fault code F.73 on a Vaillant boiler?

First check the cause described above. Then restart the appliance using the reset button. If the message comes back, a part usually needs replacing or the fault needs to be repaired by a qualified professional.

Which parts do I need for Vaillant fault code F.73?

That depends on the exact cause. In the Vaillant parts overview at Instalpunt you will find the current price and stock for each part.

Can I fix fault code F.73 myself?

You can reset the appliance and check things like the water pressure or settings yourself. Work on gas-carrying parts must be left to a certified gas engineer.