Itho Daalderop fault code 3 none
Fault code 3 none on an Itho Daalderop boiler (including KliMax 1) means: Flow temperature rises too fast. Reset the appliance once. If the code comes back, a part is usually faulty, often a temperature sensor. You can check the water pressure and settings yourself; leave work on gas-carrying parts to a certified gas engineer.
Gas, flue or flame fault? One reset is the limit; after that it is a job for a registered gas engineer. Smell gas: no switches or flames, open the windows, get out and ring your national gas emergency number or 112 from outside.
Cause
Fault code 3 none on an Itho Daalderop boiler indicates: Flow temperature rises too fast.
Fault code 3 none: what to check before you call an engineer
- Reset once: a one-off measuring glitch clears that way.
- Without opening the sealed combustion chamber, check that the sensor plug is pushed home and the wires are not chafed or burnt.
- If the code returns, the sensor or its wiring is usually faulty (short circuit or open circuit). Sensors are cheap; those inside the sealed chamber should be fitted by a qualified heating engineer.
Applies to
Itho Daalderop KliMax 1, HRT 20-22/HRT 20-22 VK, HRT 24-28/HRT 24-28 VKK, HRT 30-36/HRT 30-36 VKK, HRT 36-42, HRT 42-54.
Matching parts
Itho Daalderop parts are available from Instalpunt; shipping €9.95 to Austria, Denmark, Italy, Spain and Sweden and €12.95 to the other EU countries, free from €199, usually 3–5 working days.
Based on the cause, these original Itho Daalderop parts fit (always check the type number of your appliance):
Itho Daalderop flow sensor DN15 € 115.51
Itho Daalderop sensor cable short € 24.79
Itho Daalderop sensor cable long € 19.39
Further reading on this cause
Other Itho Daalderop codes with the same cause
- 0 1 — Open circuit flow sensor (S1)
- 0 2 — Open circuit return sensor (S2)
- 0 5 — Open circuit hot water sensor (S5)
- 0 F1 — Short circuit flow sensor (S1)
- 0 F2 — Short circuit return sensor (S2)
- 0 F5 — short circuit hot water sensor (S5)
DIY or engineer: where the line is
Keep the manual at hand, switch off the power before you open a cover and stop at the sealed combustion section. Not sure which part you need? E-mail a photo of the rating plate to info@instalpunt.com.
troubleshooting boiler faults.
From our service engineer
When your Itho Daalderop boiler shows a fault code, write down the code, what the boiler was doing and the pressure on the gauge. Reset once at most – if the same code returns, there is a cause to find, usually ignition, water pressure or flow. Gas work should always be done by a qualified engineer; in the UK that means Gas Safe registered.
Questions? E-mail info@instalpunt.com – we reply in English.
✓ Checked by Andrea Donadio, service engineer at HanVos Installaties (Netherlands) · 10 November 2026
Frequently asked questions
What does Itho Daalderop boiler fault code 3 none mean?
Flow temperature rises too fast.
How do I fix fault code 3 none on an Itho Daalderop boiler?
Work through the step-by-step list above, then reset once. A code that returns after that is rarely solved by resetting again: either a part has failed or the appliance needs a proper diagnosis by a heating engineer.
Which parts do I need for Itho Daalderop fault code 3 none?
Only the cause tells you. Open the Itho Daalderop parts overview, pick your series from the rating plate and every part is listed with its manufacturer number, price and stock, ready to ship to any EU address.
Can I fix fault code 3 none myself?
The checks in the list above, yes: pressure, power, valves, condensate trap and a single reset. Anything inside the sealed combustion section or on the gas train is for a registered gas engineer, in every EU country.
All Itho Daalderop boiler faults and codes at a glance →