Itho Daalderop heat pump fault: A, E, F, P and S codes explained

Part of the guide Which heat pump suits my home?

Short answer: an Itho Daalderop heat pump (WPU, HP-S, HP Cube or Base Cube) reports faults with a letter and a number. The A codes come from the indoor controller and concern sensors, water pressure, flow and communication with the thermostat; you can often solve these yourself. The E, F and P codes come from the outdoor unit and the refrigerant circuit and are for a certified refrigerant (F-gas) technician. The S codes concern flow rate and frost protection. The two most searched codes, A1 19 and A1 20, simply mean that the central heating water pressure is too low. Below are all the groups, what you can check yourself and which part goes with each.

Which Itho Daalderop heat pump do you have?

  • WPU (WPU 3, 5, WPU C/CO): ground source heat pump with a borehole, common in new builds between 2000 and 2015.
  • HP-S 55, 95, 110: air-to-water heat pump with an outdoor unit and an indoor unit.
  • HP Cube: hot water heat pump (cylinder) running on ventilation air.
  • Base Cube: hybrid, a boiler with a heat pump section.

The rating plate is on the indoor unit or under the front panel. The complete list of all 114 codes for these appliances is in our Itho Daalderop fault codes.

The code groups in one table

GroupComes fromWhat it is aboutYourself or engineer
A0ControllerCommunication with the heat pump interruptedYourself: plugs, reset; then an engineer
A1Controller / indoor unitTemperatuursensoren, druksensor, flowsensor, pressostaat, waterdruk, startstroom compressorWater pressure yourself; sensors and pressure switch an engineer
A3ControllerWireless thermostats, sub-controllers, batteries, valve actuators, manual modeAlmost always yourself
EOutdoor unitCompressor power supply and control, PCBs, EEPROMEngineer
FOutdoor unitOutdoor unit temperature and pressure sensors, fan, evaporating and condensing pressure, mixing valvesEngineer
POutdoor unitSafety devices: refrigerant, input current, compressor drive, high/low pressureEngineer, F-gas certified
SIndoor unitFlow rate, flow switch, frost protection, flow temperature, defrostingValves and filters yourself; then an engineer

The codes you can solve yourself

CodeMessageWhat you do
A1 19 en A1 20Central heating system water pressure too lowTop up to 1.5 to 2 bar when cold, then bleed. If the pressure drops more often: expansion vessel or leak
A3 8 en A3 9Batteries of a room thermostat or the main thermostat flatReplace the batteries, reconnect the thermostat
A3 1 en A3 2No wireless communication with a thermostatCheck distance and obstacles, batteries, re-pair the thermostat
A0 3Communication with the heat pump interruptedCheck the power supply to the outdoor unit (fuse), bus cable and plugs; then reset
A3 13Controller is in manual modeSwitch back to automatic in the menu
S02 en S10Flow rate too lowOpen radiator and underfloor heating valves, clean the filter or dirt separator, bleed; if it persists: pump or flow switch
P09Outdoor unit air circulation inadequateRemove leaves, snow and obstacles around the outdoor unit, at least 30 cm clearance
S08Defrosting failed three timesLet the ice on the evaporator melt; if it comes back in normal weather: read here what is normal

The codes that come with a part

CodeMessagePart
A1 1 to A1 11Temperature out of range or sensor open circuit/short-circuitedTemperature sensor HP-S € 18.95, sensor 22 mm WPU € 20.95, outdoor sensor WPU € 48.95
A1 12CH pressure sensor not workingCH water-side pressure sensor € 37.95
A1 15Borehole flow sensor faultyFlow sensor; have the borehole circuit bled first
A1 17 en A1 18Pressure switch (high-pressure switch) activated or faultyEngineer: too little flow or too much refrigerant pressure
F03Compressor discharge gas temperature sensorDischarge gas temperature sensor HP-S € 18.95
F09 en F10Fan not reaching its speedDC fan motor HP-S € 130.95 or reconditioned fan HP Cube € 165.95
F29 en F30Mixing valve 1 or 24-way valve HP-S € 45.95, diverter valve WPU € 122.95
E05, P03Compressor or compressor drive faultPCB compressor HP-S 55 € 301.95; compressor itself: when replacement pays off
Pump not running, pump making noiseFuse, cavitation due to low pressureCirculation pump HP-S € 384.95, CH pump Cube € 254.95
E01, F25Communication between control panel and indoor unitControl panel HP-S € 292.95, WPU 2 controller € 423.95

All parts for these appliances can be found under Itho Daalderop parts; prices include VAT.

What you should never do yourself

Anything involving the refrigerant circuit (P codes, F05, F06, F11, F12) and the compressor and its power supply (E codes) is work for a certified refrigerant (F-gas) technician. With a Base Cube, the boiler section is also a gas combustion appliance: burner, gas valve and flue only by a certified gas engineer. Sensors, valves and the pump on the water side can, however, be replaced by an installer without refrigeration qualifications.

Before you call an engineer

  • Note the complete code and the text on the display, and whether it comes back after a reset.
  • Check the water pressure on the indoor unit and top up if necessary.
  • Check that the outdoor unit has power and is unobstructed, and whether the fan runs when the heat pump calls for heat.
  • For thermostat codes (A3): batteries and distance.
  • Photograph the rating plate; with the type and the code we can have the part ready in advance, so your installer can finish the job in one visit.

Is de warmtepomp aan vervanging toe, dan vindt u de actuele modellen bij · .

Frequently asked questions

What does A1 20 mean on my Itho Daalderop heat pump?

The water pressure in the heating system is too low. Top up to 1.5 to 2 bar when cold and bleed the system. If the message returns within a few weeks, you are losing water or the expansion vessel has failed.

Can I reset the heat pump?

Yes, once. If the same code comes back, have the cause investigated. With P codes (safety cut-outs), do not keep resetting: the compressor can be damaged.

Why does my WPU show an A3 code when the unit is working normally?

A3 codes relate to the controller and the thermostats, not the heat pump. The unit usually keeps running on the last known setting. Flat batteries are the most common cause.

Are Itho Daalderop parts still available for a WPU from 2008?

For the most part, yes: sensors, valves, the controls and the pump are available. Some circuit boards are supplied as a service kit in a newer version. Send us the details from the rating plate and we will check availability.