Boiler water pressure sensor: sensor fault or genuinely low pressure, codes and which sensor fits

Part of the guide Troubleshooting a boiler fault

Short answer: if the boiler reports water pressure that is too low or too high while the pressure gauge shows a normal 1.5 to 2 bar, the water pressure sensor or its wiring is the suspect, not the system. Codes such as Remeha E.00.40, Nefit 1065, Vaillant F.73 and F.74 or AWB F 9 say exactly that: sensor open circuit, short circuit or out of range. A new sensor costs € 21 to € 54. If the pressure really is dropping, the problem is the expansion vessel or a leak, and you should read Water pressure keeps dropping. Below you can see how to tell the two apart and which sensor fits which appliance.

Sensor or switch?

Older boilers have a water pressure switch: a diaphragm with a contact that closes as soon as the pressure rises above about 0.5 to 0.8 bar. The boiler then only knows "enough pressure" or "too little pressure". Modern boilers have an electronic pressure sensor that measures the pressure continuously, usually 0 to 4 bar converted into a voltage of 0.5 to 3.5 volts. This lets the boiler show the pressure on the display, warn before it blocks and, with some brands, even top up automatically. Both are located on the hydro block or on the return pipe inside the boiler.

How to recognise a faulty sensor

What you seeLikelyWhat to do
Display shows 0.0 or an impossible value, pressure gauge reads 1.5 barSensor or plugReplace the sensor, check the wiring
Code "sensor open/short-circuit/out of range"Sensor, cable or connectorSee codes below
Code "pressure too low", display and gauge both lowGenuine pressure lossTopping up, find the cause
Pressure high when hot and low when coldExpansion vesselWater pressure keeps dropping
Message comes and goes with vibrations or after the pump startsLoose connector, break in the cableHave the plug and cable checked
Pressure is fine but the boiler will not top up automaticallySensor reads too highReplace the sensor

A simple check you can do yourself: if the boiler has a display showing the pressure as well as a separate pressure gauge, compare the two. A difference of more than 0.3 bar points to the sensor. Top up a little and see whether the display follows; if the value stays the same, the sensor is not measuring.

The codes per brand

BrandSensor faultGenuine pressure warning
RemehaE.00.40 open/below range, E.00.41 short-circuit/above range, A.00.42 sensor not detectedA.02.06 pressure below minimum
Nefit Bosch1065 sensor faulty or not connected207 / 2E 207 pressure too low, 1017
VaillantF.73 open circuit, F.74 short circuit, F.09 sensor or wiringF.21 too low, F.22 too high
Bosch1065 WCE207, 1017 W
AWBF 9 sensor broken or wiring, F.73, F.7421 too low, 22 too high
ATAG102 sensor error, C 78 out of range or not connected, Bx12sc01 open, Bx12sc02 short-circuited118 too low, 117 too high

Note the distinction the manufacturers themselves make. Remeha A.02.06 is a warning about the actual pressure, E.00.40 is about the sensor. With Nefit, 207 relates to the pressure and 1065 to the sensor. So do not order a sensor for every pressure message.

Why sensors fail

The sensor sits in the heating water. Sludge and magnetite settle in the small channel to the diaphragm, making it slow or inaccurate; that is why a dirty system produces sensor faults more often. Moisture also gets into the connector, especially on boilers where a siphon or a leaking coupling sits above the sensor. And with the small plug-in connectors, the contact can work loose through vibration. An engineer will therefore first check the plug and cable and measure the voltage before replacing the sensor.

Replacing it: what can you do yourself?

The sensor is a water-side part: no gas or flue gas is involved. Even so, on almost all boilers it is behind the casing, and opening and refitting the casing of a gas appliance is a job for a certified gas engineer. Our rule is therefore: have it done, but have the right part ready so it can be done in one visit. The work itself is quick: depressurise the boiler, release the retaining clip or union nut, remove the sensor, fit the new one with a new O-ring, refill, vent and check the reading. On Intergas the sensor is held with a clip and a retaining spring; order the spring at the same time.

Which sensor fits which appliance?

The sensors and switches below come from our catalogue; prices include VAT. Always check the appliance type; some brands have a screw-in and a clip-in version side by side.

BrandPartArticle numberPrice
IntergasHeating pressure sensor, clip, service set8063340€ 31.95
IntergasService set pressure sensor, screw-in8069577€ 53.95
IntergasPressure sensor retaining spring8063321€ 6.95
RemehaPressure switch Avanta8010259€ 27.95
RemehaPressure sensor (Calenta, Tzerra)8012610€ 36.95
RemehaWater pressure sensor8010261€ 48.95
Nefit BoschPressure sensor8029754€ 33.95
Nefit BoschPressure sensor ProLine NxT8029513€ 31.95
Nefit BoschElectronic pressure sensor with screw thread8029080€ 45.95
VaillantPressure sensor VHR 18-22/3C, 24-28/3C8058957€ 20.95
VaillantPressure sensor (ecoTEC)80501434€ 45.95
BoschPressure sensor 6 bar80200504€38.95
AWBWater pressure sensor8077371€35.95
AWBPressure sensor ThermoMaster8070762€ 32.95
ATAGPressure sensor water trap8137098€ 34.95
Itho DaalderopCH water-side pressure sensor (also heat pump)8170009€ 37.95
FerroliLow water pressure protection Mega/Dens/Star8113229€38.95

All pressure sensors and switches are listed under pressure switches. If you cannot find your appliance, send us a photo of the rating plate and of the old sensor showing the printed number; we will look up the correct part.

Frequently asked questions

Can I use the boiler with a faulty pressure sensor?

Usually not: the boiler blocks because without a pressure reading it does not know whether there is water in it. Resetting helps only temporarily at best. If the pressure gauge reads correctly, there is no danger, but the boiler will stay off until the sensor has been replaced.

How does an engineer test the sensor?

With a multimeter: a supply voltage of 5 volts at the connector and an output voltage that follows the pressure, usually around 1.5 to 2 volts at 1.5 bar. No output voltage or a fixed value means a faulty sensor; no supply points to the cable or PCB.

Is a pressure sensor universal?

The measuring technology is the same for many brands (Huba Control), but the connection, the plug and the measuring ranges differ. So use the part for your appliance type; the wrong sensor gives an incorrect pressure reading and therefore new faults.

Why does my boiler only show a pressure sensor fault when starting up?

When the pump starts, the pressure changes briefly and the appliance vibrates. A connector that is only just making contact loses it at that moment. Have the plug checked and replace the cable if necessary; the sensor itself is often still fine.