Itho Daalderop fault code Flashing red
Fault code Flashing red on an Itho Daalderop heat pump (including WPU 5G) means: Under-/overvoltage. Pump module temperature too high. Reset the appliance once. If the code comes back, a part is usually faulty, often the central heating pump. You can check the water pressure and settings yourself; leave work on gas-carrying parts to a certified gas engineer.
Gas, flue or flame fault? One reset is the limit; after that it is a job for a registered gas engineer. Smell gas: no switches or flames, open the windows, get out and ring your national gas emergency number or 112 from outside.
Cause
Fault code Flashing red on an Itho Daalderop heat pump indicates: Under-/overvoltage. Pump module temperature too high.
Fault code Flashing red: what to check before you call an engineer
- Find the pressure gauge (or the bar reading on the display). With the heating cold, a sealed system should sit between 1.5 and 2 bar wherever you live in Europe.
- Bleed the radiators with a radiator key, ground floor first, and keep a cloth under the valve. Bleeding lowers the pressure, so check the gauge again afterwards.
- With the heating calling for heat, rest a hand on the circulation pump or listen closely: a running pump hums and vibrates slightly.
- Press reset once and give the appliance a minute. If the code returns straight away, stop there: repeated resets hide a real fault and can lock the appliance out.
- Nothing at all, or the code returns? The pump is seized or its electronics have failed. Note the pump type on its label before ordering.
Applies to
Itho Daalderop WPU 5G, 18-C, 18-COE, 18-E, 18-GE, 18-KC, 25-C, 25-COE, 25-E.
Matching parts
Itho Daalderop parts are available from Instalpunt; shipping €9.95 to Austria, Denmark, Italy, Spain and Sweden and €12.95 to the other EU countries, free from €199, usually 3–5 working days.
Based on the cause, these original Itho Daalderop parts fit (always check the type number of your appliance):
Itho Daalderop pump Wilo PARA € 209.88
Further reading on this cause
Other Itho Daalderop codes with the same cause
- A0 3 — Communication with the heat pump has been interrupted.
- A1 22 — The phase sequence in the wall socket is not clockwise on the heat pump.
- A1 23 — There is no clockwise rotating field on the incoming 3-phase supply to the heat pump.
- P10 — The input voltage of the heat pump is too high or too low.
- Pump not running — Pump has no supply voltage.
- Off — Energy saving during standby of the heat pump.
DIY or engineer: where the line is
Keep the manual at hand, switch off the power before you open a cover and stop at the sealed combustion section. Not sure which part you need? E-mail a photo of the rating plate to info@instalpunt.com.
From our service engineer
If your Itho Daalderop heat pump reports a fault, check whether the outdoor unit is running and note the code. It is often flow or defrosting in freezing weather. Only an F-gas certified engineer may work on the refrigerant circuit.
Questions? E-mail info@instalpunt.com – we reply in English.
✓ Checked by Andrea Donadio, service engineer at HanVos Installaties (Netherlands) · 10 November 2026
Frequently asked questions
What does Itho Daalderop heat pump fault code Flashing red mean?
Under-/overvoltage. Pump module temperature too high.
How do I fix fault code Flashing red on an Itho Daalderop heat pump?
Work through the step-by-step list above, then reset once. A code that returns after that is rarely solved by resetting again: either a part has failed or the appliance needs a proper diagnosis by a heating engineer.
Which parts do I need for Itho Daalderop fault code Flashing red?
Only the cause tells you. Open the Itho Daalderop parts overview, pick your series from the rating plate and every part is listed with its manufacturer number, price and stock, ready to ship to any EU address.
Can I fix fault code Flashing red myself?
The checks in the list above, yes: pressure, power, valves, condensate trap and a single reset. Anything inside the sealed combustion section or on the gas train is for a registered gas engineer, in every EU country.
All Itho Daalderop heat pump faults and codes at a glance →