Boiler with display and pressure gauge
Boiler fault codes

Remeha boiler faults: fault codes, causes and parts (page 6 of 6)

Codes 751 to 806 of the 806 fault codes for Remeha. Looking for a specific code? Use the search on the first page.

Remeha boiler fault codes 751 to 806 of 806

The code list is split over 6 pages. Looking for a specific code? Use the search on the first page: it searches all 806 codes in one go.

CodeCause
H03.08False flame
H03.09Low voltage
H03.09Low voltage.
H03.17Fault in gas control system.
H03.17Fault in gas control system
H03.254Unknown error
H03.254Unknown error.
H03.26Boiler calibration request.
H03.26Boiler calibration request
H03.28Synchronisation error
H03.28Synchronisation error.
H03.31Blocked chimney fault.
H03.31Blocked chimney fault
H03.54Unknown error
H03.54Unknown error.
H20.36Manual calibration failed.
H20.36Manual calibration failed
H20.39No primary calibration
H20.39No primary calibration.
H20.40No gas configuration.
H20.40No gas configuration
Knipperend red signaalFault:
b 08Too little air transport during pre-purge. After 4 restarts (5 starts) the boiler goes into lockout with code 08
b 24Flow and return sensors have been swapped
b 25Maximum permissible rate of rise of the heat exchanger temperature exceeded
b 26If minimum gas pressure switch LD connected (option): below minimum gas pressure
b 30Maximum permissible difference between flow and return temperature exceeded
b 43One or more set parameters are outside the range
b 52Maximum flue gas temperature exceeded.
b 62If water pressure sensor connected (option): water pressure is too low
b 88Blocking input is open.
b XXLockout mode
b25Normal operating modes and therefore does not indicate a fault
b26The contacts of the external protection opened during heat demand
b28Fan defective or not properly fitted
b29Fan continues to run after the post-purge time or speed indication is not correct
b30Normal operating modes and therefore does not indicate a fault
u 401Temperature detected by the limit thermostat on the generator body is HIGH
u 402Temperature detected by the flue gas thermostat HIGH
u 406Temperature detected by the ambient sensor LOW.
u 407Temperature measured by the condenser inlet sensor, flue gas sensor or generator fin sensor HIGH.
u 410Insufficient water flow (the circulation pump is on and the water flow regulator/flow meter detects too low a flow).
u 411Insufficient rotation of the hydraulic pump.
u 412Burner does not switch on.
u 429Gas valve remained off for 5 seconds (with burner control unit switched on).
u 436Fan faulty
u 446Hot water inlet temperature too high (when the appliance is operating).
u 447Hot water temperature too low (when the appliance is operating).
u 448High hot water temperature differential.
u 452Activation of the defrosting function. Defrosting is activated if at least 90 minutes have elapsed since the previous defrosting (or 180 minutes if the temperature is lower than -5 °C), if the burner control unit has been switched on for at least 15 minutes and if the ambient temperature, the hot water at the inlet and the evaporator require it to be activated.
u 453The warning is generated if the system is operating in conditioning mode and the liquid flow meter/water flow meter of the hot module is closed.
u 478High hot water outlet temperature
u 479Water temperature at the burner inlet has dropped below 4°C (the code generated signals the actual activation of the antifreeze function). In that case the antifreeze function activates the circulation pump in the system. If the same temperature drops further below 3°C, the antifreeze function also switches on the burner control unit.
u 480Parameters incomplete
u 481Data Bank 1 not valid, while Data Bank 2 OK.
u 482Data Bank 2 not valid, while Data Bank 1 OK.