Heat pump outdoor unit
Heat pump fault codes

Atlantic heat pump faults: fault codes, causes and parts

All 126 fault codes for Atlantic heat pumps, plus the faults that show no code. Type your code or choose your symptom.

In brief

A fault on an Atlantic heat pump usually means that the appliance has locked out or is reporting a fault code. Note the code on the display and look it up below: for each code you will find its meaning, checks you can safely do yourself and the parts that are often checked or replaced. Frequently searched: No heating (fuse CF2), 60 (ambient sensor 1), 370 (thermodynamic generator). No code? Check the power supply, the settings and the filters, and reset once. If the fault comes back, call in a qualified professional.

Most searched Atlantic faults

These are the codes that visitors to this site search for most often.

See the 25 most searched fault codes of 2026, with the figures behind them →

Atlantic heat pump faults without a code on the display

Not every fault shows a code. These are the symptoms we come across most often with Atlantic appliances, with what you can check yourself before calling someone out.

Heat pump no longer produces heat

Check that the system has enough pressure and whether there is a message on the display or in the app. After a power cut, some units start up in a safe mode and have to be released manually. View the matching parts → Read also: heat pump freezes or defrosts constantly →

Outdoor unit freezes or defrosts constantly

A thin layer of ice in frosty weather is normal; the unit defrosts itself periodically. If the ice stays or the unit defrosts every few minutes, the airflow is obstructed or something is wrong with the defrost control. View the matching parts → Read also: heat pump freezes or defrosts constantly →

Too little or too cold hot water

Check the set hot water temperature and whether the electric immersion heater is enabled. A sharp drop in hot water capacity often points to a faulty cylinder sensor or a worn anode in the tank. View the matching parts → Read also: replace the anode before the tank fails →

Noise or vibrations

A noticeably louder noise than normal usually comes from the fan or from vibrations carried through the pipework. Check that the unit stands clear and that the anti-vibration mounts are intact. View the matching parts → Read also: noise and ice on the outdoor unit →

All 126 Atlantic heat pump fault codes

CodeCause
-Power supply
-Fuse CF1 0643XU: 250V 15A / 1043XU: 250V 25A / 1242XU: 250V T30A / 1643XU: 250V T30A.
-Fuse CF3 (250V 3A)
-Fuse CF4 0643XU: 250V 3A / 1043XU: 250V 3A.
-PCB (Main)
10Outdoor temperature sensor: Short circuit. Sensor disconnected or switched off. Sensor defective. Other fault.
10Outdoor temp sensor: Short circuit. Sensor disconnected or switched off. Sensor defective. Other fault.
11Serial communication error after operation
11Serial communication error during operation
127Anti-legionella temperature: Anti-legionella temperature setting not reached.
212Internal communication error: Sensor disconnected or switched off.
23Combination of indoor unit and outdoor unit differs
32Flow sensor 2: Short circuit. Sensor disconnected or switched off. Sensor defective. Other fault.
33HP flow sensor: Short circuit. Sensor disconnected or switched off. Sensor defective. Other fault.
369External: Outdoor safety EX3 switch-off
370Thermodynamic generator: See details in "Outdoor unit faults"
370Thermodynamic generator: See details in "Outdoor unit faults"
44HP return sensor: Short circuit. Sensor disconnected or switched off. Sensor defective. Other fault.
441BX31 no function: Short circuit. Sensor disconnected or switched off. Sensor defective. Other fault.
442BX32 no function: Short circuit. Sensor disconnected or switched off. Sensor defective. Other fault.
443BX33 no function: Short circuit. Sensor disconnected or switched off. Sensor defective. Other fault.
444BX34 no function: Short circuit. Sensor disconnected or switched off. Sensor defective. Other fault.
50DHW sensor 1: Short circuit. Sensor disconnected or switched off. Sensor defective. Other fault.
516HP absent: Connection lost between controller and HP.
60Ambient sensor 1: Short circuit. Sensor disconnected or switched off. Sensor defective. Other fault.
62Outdoor unit main PCB fault
63Inverter fault
65Outdoor unit IPM fault
65Incorrect IPM board temperature.
65Ambient sensor 2: Short circuit. Sensor disconnected or switched off. Sensor defective. Other fault.
65Incorrect IPM board temperature
71Discharge-side temperature sensor fault
72Compressor temperature sensor fault
73Evaporator (centre) temperature sensor fault
73Evaporator (outlet) temperature sensor fault
74Outdoor temperature sensor fault
77Outdoor unit heatsink temp. thermistor fault
78Expansion device temperature sensor fault
83BSB short circuit. Wiring problem (between the ambient sensor or control panel, display and controller).
84Compressor current fault
86Pressure switch fault
86Current sensor fault
94Shutdown detected
95Compressor rotor position detection fault, compressor start fault
97Outdoor unit fan fault
A0DC voltage fault: Fan motor
A0DC voltage fault: Fuse CF6; 1242XU: 250V T3.15A / 1643XU: 250V T3.15A
A0DC voltage fault: Fuse CF7; 1043XU: 250V T3.15A / 1242XU: 250V T3.15A / 1643XU: 250V T3.15A
A0DC voltage fault: Pump
A0DC voltage fault: Reactor
A0DC voltage fault: PCB
A0DC voltage fault: Power supply
A1Discharge temperature fault: Sensor, discharge temp.
A1Gas leak
A1Discharge-side temperature protection
A2Overcurrent protection action. DC current detection: Supply voltage too low.
A2Overcurrent protection action. DC current detection: Abnormal operation due to too low or too high load.
A2Overcurrent protection action. DC current detection: PCB.
A2Overcurrent protection action. DC current detection: Momentary interruption of power supply (during lightning).
A2Overcurrent protection action. DC current detection: Compressor.
A3PCB
A3Compressor temperature protection
A4Protective action against overload: AC current detection. Abnormal operation due to too low or too high load.
A4Protective action against overload: AC current detection. Supply voltage drop.
A4Protective action against overload: AC current detection. Momentary power interruption (in case of lightning strike).
A5Abnormal compressor rotation: Abnormal operation due to too low or too high load.
A5Abnormal compressor rotation: Supply voltage drop.
A5Abnormal compressor rotation: Fuse CF6 0643XU: 250V 15A 1043XU: 250V 25A.
A5Abnormal compressor rotation: Water pump and/or water circuit blocked.
A5Abnormal compressor rotation: Supply voltage too low.
A5Abnormal compressor rotation: Momentary power interruption (in case of lightning strike).
A5Abnormal compressor rotation: Compressor or PCB.
A5Abnormally low pressure
A6Suction temperature sensor fault. Sensor, suction temp.
A7Defrost temperature sensor fault. Sensor, defrost temp.
A8Discharge temperature sensor fault. Sensor, discharge temp.
ACIncorrect outdoor unit radiator temperature
C1Upper fan motor for units 1242XU 1643XU: Fuse CF7 (250V T3.15A). Fan motor (*2). PCB.
C2Outdoor temperature sensor fault.
C3Fan motor fault for units 0643XU 1043XU. Lower fan motor fault for units 1242XU 1643XU: Fan motor.
C3Fan motor fault for units 0643XU 1043XU. Lower fan motor fault for units 1242XU 1643XU: PCB.
C3Fan motor fault for units 0643XU 1043XU. Lower fan motor fault for units 1242XU 1643XU: Fuse CF6 1242XU: 250V T3.15A / 1643XU: 250V T3.15A.
C3Fan motor fault for units 0643XU 1043XU. Lower fan motor fault for units 1242XU 1643XU: Fuse CF7 1043XU: 250V T3.15A.
C4Temperature rise of PCB (Main) (above 110 °C). Incorrect installation.
C4Temperature rise of PCB (Main) (above 110 °C). Sensor, PCB temp.
C5PCB (Main) sensor fault. Sensor, PCB temp.
C6PCB (Main) fault: PCB.
C7PCB (Remote control) serial fault. Not applicable to Hybrid add-on: Incorrect wiring or abnormal contact (PCB).
C7PCB (Remote control) serial fault. Not applicable to Hybrid add-on: PCB.
C7PCB (Remote control) serial fault. Not applicable to Hybrid add-on: EARTH WIRE.
C8PCB fault.
E4Outgoing water temperature sensor fault. Sensor, outgoing water temp.
E5Return water temperature sensor fault. Sensor, return water temp.
E6Plate heat exchanger temperature sensor fault. Sensor, plate heat exchanger temp.
F5PCB communication error: • Incorrect wiring of PCB (Main). • Loose connection cable or contacts on Interface.
F5PCB communication error: PCB.
F5PCB communication error: PCB (Remote control)
FUHigh pressure switch is operating. Pressure switch is operating: Outdoor air recirculation.
FUHigh pressure switch is operating. Pressure switch is operating: Blocked water circuit.
No heatingFuse CF2: 0643XU: 250V T3.15A / 1043XU: 250V T3.15A / 1242XU: 250V T5A / 1643XU: 250V T5A.
No heatingFour-way valve
No heatingDefrost heater
No heatingCheck for blockage of the air inlet/outlet.
No heatingShort cycling (insufficient air circulation).
No heatingSensor, outgoing water temp. and return water temp.
No heatingGas leak
No heatingBlocked water circuit. Electronic expansion vessel.
PCB not workingPCB cannot be started. PCB shows no display: Power supply wire of PCB.
PCB not workingPCB cannot be started. PCB shows no display: PCB.
L0EEPROM error
L2Outdoor temperature sensor fault.
L3Buffer temperature sensor fault.
L4Mixed water temperature sensor fault.
L5Humidity sensor fault.
L6Flow switch fault: Water pump and/or water circuit blocked.
L6Flow switch fault: Flow switch.
L7Mixing valve fault: Water pump and/or water circuit blocked.
L7Mixing valve fault: PCB.
L7Mixing valve fault: Mixing valve.
P1Pump fault: Pump
P1Pump fault: PCB
P1Pump fault: Water pump and/or water circuit blocked.
P3High pressure switch fault. High pressure switch.
U1Compressor overheat protection relay operated (1643XU): Compressor overheat protection relay.
U1Compressor overheat protection relay operated (1643XU): Gas leak.
U1Compressor overheat protection relay operated (1242XU).

Order parts for your Atlantic heat pump

Atlantic parts are available from Instalpunt; shipping to EU countries from €17.95 (€24.95 for more distant countries), usually 3–5 working days.

View Atlantic parts →

Frequently asked questions about Atlantic faults

What does a fault on an Atlantic heat pump mean?

The appliance is reporting that it has shut itself down or cannot continue. The code on the display points to the group of causes: ignition, water pressure, a sensor, the fan or communication with the thermostat. The table above shows, for each code, what Atlantic means by it.

How do I reset my Atlantic heat pump?

The reset button is on the control panel of your Atlantic heat pump; on most appliances you hold it down for two to five seconds until the display responds. Reset once. If the same fault comes straight back, resetting will not solve it and a part or a setting needs attention. Always consult the manual for your model: the position of the button and how long to press it differ per series.

Can I fix an Atlantic fault myself?

You can top up the water pressure, bleed the system, replace filters and clean a siphon yourself. Anything behind the sealed section of a gas appliance is a different matter: work on the gas valve, burner, heat exchanger and flue must be carried out by a certified gas engineer.