Remeha fault code No signal
Fault code No signal on a Remeha boiler (including Tzerra) means: No supply voltage:. Reset the appliance once. If the code comes back, a part is usually faulty. You can check the water pressure and settings yourself; leave work on gas-carrying parts to a certified gas engineer.
Gas, flue or flame fault? One reset is the limit; after that it is a job for a registered gas engineer. Smell gas: no switches or flames, open the windows, get out and ring your national gas emergency number or 112 from outside.
Cause
Fault code No signal on a Remeha boiler indicates: No supply voltage:.
Fault code No signal: what to check before you call an engineer
- Switch the appliance off at the fused spur or plug for half a minute, then back on. This clears many electronic hiccups without touching anything inside.
- If the code refers to the thermostat or a communication link, check that the thermostat has power or fresh batteries and that its wires are seated in the terminals.
- Press reset once and give the appliance a minute. If the code returns straight away, stop there: repeated resets hide a real fault and can lock the appliance out.
- Code back again? The control board (PCB) or burner control unit is the likely culprit. Have the fault memory read out first; a board ordered on a guess is expensive and cannot be returned once fitted.
Applies to
Remeha Tzerra, Plus M 24C Combi CW3, Plus M 28C Combi CW4, Plus M 39C Combi CW5.
Matching parts
Remeha parts are available from Instalpunt; shipping €9.95 to Austria, Denmark, Italy, Spain and Sweden and €12.95 to the other EU countries, free from €199, usually 3–5 working days.
Parts per Remeha-series: Tzerra Ace · Tzerra · Avanta Ace · Avanta · Calenta Ace · Calenta · Quinta Ace · Quinta.
No single part is behind this code. These are the parts that most often fit this appliance:
Remeha automatic air vent for e.g. Tzerra 39kW Combi S101770 € 20.30
Remeha CH flow filter € 24.59
Remeha flow sensor for Tzerra and Tzerra Ace € 42.79
DIY or engineer: where the line is
Keep the manual at hand, switch off the power before you open a cover and stop at the sealed combustion section. Not sure which part you need? E-mail a photo of the rating plate to info@instalpunt.com.
troubleshooting boiler faults.
From our service engineer
When your Remeha boiler shows a fault code, write down the code, what the boiler was doing and the pressure on the gauge. Reset once at most – if the same code returns, there is a cause to find, usually ignition, water pressure or flow. Gas work should always be done by a qualified engineer; in the UK that means Gas Safe registered.
Questions? E-mail info@instalpunt.com – we reply in English.
✓ Checked by Andrea Donadio, service engineer at HanVos Installaties (Netherlands) · 10 November 2026
Frequently asked questions
What does Remeha boiler fault code No signal mean?
No supply voltage:.
How do I fix fault code No signal on a Remeha boiler?
Work through the step-by-step list above, then reset once. A code that returns after that is rarely solved by resetting again: either a part has failed or the appliance needs a proper diagnosis by a heating engineer.
Which parts do I need for Remeha fault code No signal?
Only the cause tells you. Open the Remeha parts overview, pick your series from the rating plate and every part is listed with its manufacturer number, price and stock, ready to ship to any EU address.
Can I fix fault code No signal myself?
The checks in the list above, yes: pressure, power, valves, condensate trap and a single reset. Anything inside the sealed combustion section or on the gas train is for a registered gas engineer, in every EU country.
All Remeha boiler faults and codes at a glance →