Boiler fault codes

Remeha boiler faults: fault codes, causes and parts

All 806 fault codes for Remeha boilers, plus the faults that show no code. Type your code or choose your symptom.

In brief

A fault on a Remeha boiler usually means that the appliance has locked out or is reporting a fault code. Note the code on the display and look it up below: for each code you will find its meaning, checks you can safely do yourself and the parts that are often checked or replaced. Frequently searched: E14 (5 failed burner starts), E36 (5x flame loss), E9 (fan not running). No code? Check the water pressure (1.5 to 2 bar when cold), the power supply and the gas tap, and reset once. If the fault comes back, call in a certified gas engineer. If you smell gas, call your national gas emergency number or 112 immediately.

Most searched Remeha faults

These are the codes that visitors to this site search for most often.

See the 25 most searched fault codes of 2026, with the figures behind them →

Remeha boiler faults without a code on the display

Not every fault shows a code. These are the symptoms we come across most often with Remeha appliances, with what you can check yourself before calling someone out.

No hot water, but the heating works

The boiler heats the radiators but not the tap water. Check that the hot water function is switched on in the display (on some appliances it is called DHW mode or summer mode) and that the hot water valve under the boiler is open. If the water stays cold, this usually points to a fouled or leaking DHW heat exchanger, a faulty diverter valve or a DHW sensor giving incorrect readings. View the matching parts → Read the full explanation: no hot water, six causes →

Water pressure keeps dropping

Top up to 1.5–2 bar when cold and bleed the radiators. If the pressure drops again within a few days, the expansion vessel has often lost its pre-charge or there is a small leak in the system. A pressure relief valve that keeps dripping gives the same symptom. View the matching parts → Read the full explanation: water pressure keeps dropping – expansion vessel or leak? →

Boiler shuts down and locks out

The appliance shuts down and only starts again after a reset. Reset once; if the fault comes straight back, leave the reset button alone. Repeatedly resetting a locked-out boiler is not without risk: the safety device trips for a reason. View the matching parts → Read also: is the boiler cutting out because of a sensor or overheating? →

Radiators stay cold

Check that the thermostat is calling for heat, that the radiator valves are open and that the system has enough pressure. If everything stays cold while the boiler is firing, the circulation pump is often not running or the diverter valve is stuck in the hot water position. View the matching parts → Read the full explanation: radiators stay cold →

Ticking, humming or boiling noise

A banging noise at start-up usually points to air or limescale in the heat exchanger. A humming pump may have a worn bearing. A rattling fan is often rubbing or dirty. View the matching parts → Read also: replacing the fan – what to rule out first →

Water under the boiler

Check where it is coming from: the condensate drain (siphon blocked or cracked), the pressure relief valve (pressure too high or faulty expansion vessel) or a fitting. If in doubt, switch the boiler off and close the water supply. View the matching parts → Read the full explanation: water under the boiler – condensate or a leak? →

Remeha boiler fault codes 1 to 150 of 806

The code list is split over 6 pages. Looking for a specific code? Use the search at the top of this page: it searches all 806 codes in one go.

CodeCause
0.0IMS minimum position is above IMS start position
0.1IMS minimum position not detected
0.2IMS end position (100%) not detected
00.Incorrect flame detection
00.Flame simulation, incorrect flame signal
01.Short circuit in 24 V circuit
02.No flame formation or no ionisation (after 5 start attempts). No ignition spark.
02.No flame formation or no ionisation (after 5 start attempts). Ignition spark present, but no flame.
02.No flame formation or no ionisation (after 5 start attempts). Flame present, but insufficient ionisation (< 3 µA).
02.No flame formation or no ionisation (after 5 start attempts), no ignition spark.
02.No flame formation or no ionisation (after 5 start attempts). Flame present, but insufficient ionisation (< 3 µA).
02.Ignition spark present, but no flame
02.No flame formation or no ionisation (after 5 start attempts), Ignition spark present, but no flame.
02.No flame formation or no ionisation (after 5 start attempts), Flame present, but insufficient ionisation (< 3 µA)
02.No ignition spark or no ionisation
02.No flame formation
05.External influences
08.Air transport (lockout follows if no signal is received 60 s after restart)
08.Air transport
11Internal communication bus fault
11.Internal communication bus fault
12External protection
12.Control unit fault / Fuse F1 (3.15 AT) defective
12.External protection
12.Control unit fault / Fuse F1 (3.15 AT) defective
18Maximum water temp. reached
18High flow temperature
18.High flow temperature
19Return temperature too high
19.Return temperature too high
24Temperature sensor
24Flow and return swapped
24.Flow and return swapped
25Maximum rise
25.Maximum temperature rise, rate of rise of flow temperature too high
28Fan does not run. Fan is seized or rotor does not turn. No voltage or PWM signal due to corrosion of cable or connector
28.Fan does not run. Fan is seized or rotor does not turn. No voltage or PWM signal due to corrosion of cable or connector
29Fan continues to run or signal not correct Check the connector on the fan and control unit. Fan faulty. Natural draught
29.Fan continues to run or signal not correct Check the connector on the fan and control unit. Fan faulty. Natural draught
3Gas valve defective
30Max. dT exceeded
30Max. temp. difference
30.Max. dT exceeded
31Temperature sensor
31Flow temperature sensor fault
31.Flow temperature sensor fault
32Short circuit of return temperature sensor
32Return temperature sensor fault
32.Return temperature sensor fault
33.Outdoor temperature sensor fault
34Outdoor temperature sensor fault
34.Temperature sensor fault
35Flue gas temperature sensor fault
36Flow temperature sensor fault
36.Flow temperature sensor fault
37Return temperature sensor fault
4Control fault: voltage interruption during fault lockout
4Voltage loss during fault lockout
4Maximum heat exchanger temperature rise exceeded
40Flue gas temperature sensor fault
40Programming error
40.Programming error
43Parameters out of range
43.Programming error
5External influences
5Poor flame signal
52Flue gas temperature too high
61Air pressure differential switch does not open
61Air transport Air pressure differential switch does not open
61.Air pressure differential switch does not open
77Ionisation lost during operation (after 4 restarts during 1 heat demand)
77.Ionisation lost during operation (after 4 restarts during 1 heat demand)
8Air transport
8Air pressure differential switch does not close
8Programming error
83Heat exchanger temperature too high
86Start position (0%) and end position (100%) of IMS detected simultaneously
87Sealing position of IMS not detected
89Gas leak
93Sealing position and minimum position of IMS detected simultaneously
95Temperature sensor fault
96Temperature sensor fault
A.00.28The temperature sensor is not connected or measures a temperature below the recommended range
A.00.29The temperature sensor is short-circuited or measures a temperature above the recommended range
A.00.34Outdoor temperature sensor expected but not detected
A.00.34Outdoor temperature sensor was expected but has not been detected
A.00.34TOutdoor missing Outdoor temperature sensor was expected but has not been detected
A.00.42Water pressure sensor was expected but has not been detected
A.00.42Water pressure missing Water pressure sensor was expected but has not been detected
A.01.23Poor combustion
A.01.23Poor combustion Poor combustion
A.02.06Low pressure in the heating circuit
A.02.33Automatic filling of the system takes too long. Automatic filling is stopped
A.02.34Automatic filling will not be started because the time between two fill attempts is too short.
A.02.36Lockout: communication with a functional component has been lost
A.02.36Functional device disconnected
A.02.36Funct. device missing Functional device is disconnected
A.02.37Warning: communication with a non-critical component has been lost
A.02.37Non-crit. device missing Non-critical device is disconnected
A.02.37Passive functional device disconnected
A.02.45CAN connection matrix full
A.02.45Connection error
A.02.45CAN conn. matrix full CAN connection matrix full
A.02.46CAN admin. device full
A.02.46CAN admin. device full CAN admin. device full
A.02.46Device priority error
A.02.48Function group configuration error
A.02.48Unit function configuration error
A.02.48Config. error function group Function group configuration error
A.02.49Initialisation node failed
A.02.49Init. node failed Initialisation node failed
A.02.49Node initialisation failed
A.02.54OpenTherm bus supply error
A.02.55Incorrect or missing serial number
A.02.55Invalid or missing serial no. Invalid or missing device serial number
A.02.55Invalid or missing device serial number
A.02.69Demo mode active Demo mode active
A.02.69Demo mode active
A.02.76Memory full The reserved memory space for customised parameter values is full. User changes no longer possible
A.02.76Internal memory reserved for full customisation of the settings. No further changes can be made
A.02.76The reserved memory space for customised parameter values is full. User changes no longer possible
A.02.80Missing cascade controller Missing cascade controller
A.02.80Missing cascade controller
A.08.02Shower time over The time reserved for showering has elapsed
A.08.02The time reserved for showering has elapsed
A00.34Outdoor sensor missing
A00.34Outdoor sensor missing.
A01.21Maximum DHW temperature gradient Level3 exceeded
A02.06Warning: water pressure is lower than the minimum water pressure
A02.06Low pressure in the heating circuit
A02.06Low pressure in the heating circuit.
A02.18Object Dictionary error
A02.18Incorrect configuration
A02.18Incorrect configuration.
A02.33Fault: maximum fill time exceeded
A02.33Fault: maximum fill time exceeded.
A02.34For automatic filling, the minimum time interval between two requests has not been reached.
A02.36Functional device disconnected
A02.36Functional device disconnected.
A02.37Passive functional device disconnected
A02.37Passive functional device disconnected.
A02.37Non-critical device is disconnected
A02.45CAN connection matrix full
A02.45Connection error
A02.45Connection error.
A02.46Device priority error
A02.46Device priority error.
A02.46CAN admin. device full
A02.48Unit function configuration error
A02.48Unit function configuration error.

Order parts for your Remeha boiler

Remeha parts are available from Instalpunt; shipping to EU countries from €12.95 (€16.95 for more distant countries), usually 3–5 working days.

Parts per Remeha-series: Tzerra Ace · Tzerra · Avanta Ace · Avanta · Calenta Ace · Calenta · Quinta Ace · Quinta.

View Remeha parts →

Frequently asked questions about Remeha faults

What does a fault on a Remeha boiler mean?

The appliance is reporting that it has shut itself down or cannot continue. The code on the display points to the group of causes: ignition, water pressure, a sensor, the fan or communication with the thermostat. The table above shows, for each code, what Remeha means by it.

How do I reset my Remeha boiler?

The reset button is on the control panel of your Remeha boiler; on most appliances you hold it down for two to five seconds until the display responds. Reset once. If the same fault comes straight back, resetting will not solve it and a part or a setting needs attention. Always consult the manual for your model: the position of the button and how long to press it differ per series.

Can I fix a Remeha fault myself?

You can top up the water pressure, bleed the system, replace filters and clean a siphon yourself. Anything behind the sealed section of a gas appliance is a different matter: work on the gas valve, burner, heat exchanger and flue must be carried out by a certified gas engineer.

How much does it cost to fix a fault?

That depends on the cause and whether a part is needed. With us you can see the part straight away with its price and delivery time, so you know where you stand in advance. If you call in an engineer, always ask about the call-out charge and hourly rate before they come.

Where can I find the right part for my Remeha?

Check the rating plate for the exact type and use it to search our catalogue, or search directly by the manufacturer number of the faulty part. Each part lists the appliances it fits.

Scroll to Top