Short answer: Most heat pump error codes fall into a handful of groups: water pressure and flow in the heating circuit, temperature sensors, communication or wiring between the indoor and outdoor unit, the electric backup heater, and the refrigerant circuit. Read the code on the indoor unit or controller, note the model, then check power, settings, water pressure and filters and reset once. Anything inside the refrigerant circuit is work for an F-gas certified technician.
Updated November 2026. Based on our own fault code database for heat pumps on instalpunt.com (code meanings and formats per brand, as published on 29 November 2026), the manufacturers' documentation it is built from, and the European Commission's page on the F-gas Regulation (EU) 2024/573. Always check the manual of your own appliance; codes differ between models and software versions.
Where to find the code
On a split or monobloc air-to-water heat pump, the code usually appears on the indoor unit or the system controller, not on the outdoor unit. Start with the brand shown there. Copy the code exactly, including letters, dots and hyphens, and note the full model name from the rating plate. A hybrid system adds one more step: some codes concern the gas boiler, not the heat pump.
Formats differ a lot between makers. Our heat pump fault codes section currently covers eight brands:
| Brand | What a code looks like | Examples |
|---|---|---|
| Vaillant | F, a dot and a number | F.723, F.9998 |
| Remeha | a letter and a dotted number; H for faults, E for lockouts | H02.07, E02.24 |
| NIBE | numbered alarms | 1, 52, 225 |
| Itho Daalderop | letter group plus number; some faults only as a flashing red light | A1 20, A3 2 |
| ATAG | mostly numbers, some letter-number codes | 937, 2P7 |
| Atlantic | numbers, a few plain-text messages | 60, 370 |
| Intergas | n for a notification, F for a fault | n013, F050 |
| Inventum | numbers, sometimes with an F- prefix | 95, F-94 |
The five groups behind most codes
When we sort the codes our visitors look up most often by cause, the same groups keep appearing. The examples below come from our database.
1. Water pressure and flow
A heat pump needs enough water moving through the heating circuit. Low pressure or no flow stops it quickly. Examples: Itho Daalderop A1 20 (heating system water pressure too low), Inventum 95 (water pressure critically low, below 0.3 bar), Remeha H02.07 (water pressure error), ATAG 937 (no circulation) and Vaillant F.723 (pressure loss in the emitter circuit due to a leak or air pocket, or a faulty pressure sensor). Check the pressure gauge, bleed the system if needed and look for closed valves or a blocked filter. If the pressure keeps dropping, our guide on heating pressure that keeps falling applies to heat pump systems too.
2. Temperature sensors
Heat pumps rely on many sensors: outdoor air, flow, return, hot water cylinder and refrigerant temperatures. Examples: NIBE 1 (outdoor sensor BT1), Atlantic 60 (ambient sensor short circuit or disconnected) and Remeha H00.51 (return temperature sensor). A loose plug or a damaged cable can trigger the same code as a failed sensor, so check the connection before ordering a new one.
3. Communication and power supply
Indoor and outdoor units talk to each other over a cable or bus. Examples: Vaillant F.9998 (cable not connected or wrongly connected, outdoor unit without supply voltage), Remeha H06.28 (communication fault between indoor and outdoor unit) and Intergas n052 (OpenTherm connection error with the boiler in a hybrid set-up). Check that both units have power and that no breaker has tripped.
4. Electric backup heater
Many heat pumps have an electric element for backup or hot water. Its safety thermostat trips if water does not flow or the circuit is not full. Examples: NIBE 52 (maximum thermostat of the auxiliary element tripped) and Vaillant F.1100 (safety temperature limiter of the electric auxiliary heater opened, for instance because the flow rate is too low or there is air in the circuit). The cause is often a flow problem, not the element itself.
5. Refrigerant circuit
Codes such as ATAG 9E21 (low refrigerant charge), NIBE 229 (compressor high pressure alarm) or Vaillant F.732 (compressor outlet temperature above 130 °C) point to the refrigerant side. You cannot fix these yourself. Under the EU F-gas rules, work on the refrigerant circuit must be done by a certified technician; see our guide to the F-gas rules. Before you agree to a new compressor, read heat pump compressor failed?
What to check first, in this order
- Power: both indoor and outdoor unit, including the breakers in the fuse box.
- Settings: operating mode, schedule, holiday mode and target temperatures on the controller.
- Water pressure: the value recommended in your manual, read when the system is cold.
- Filters: a blocked strainer or dirt filter in the heating circuit can stop the flow.
- Outdoor unit: free airflow, no snow or ice blocking the coil or the drain. In winter, a defrost cycle is normal; see ice on your heat pump's outdoor unit.
- One reset: if the code returns, stop and note the code, model and what you checked for the technician.
Instalpunt supplies genuine heat pump parts across the EU, such as sensors, pumps and backup heaters; complete heat pumps are not shipped outside the Netherlands and Belgium. We do not carry out repairs or installations.
Frequently asked questions
Is a code on the outdoor unit the same as on the controller?
Not always. Many systems show the main code on the indoor unit or controller. Use the code from the display you normally operate and check your manual for codes shown on the outdoor unit itself.
Can I reset a heat pump fault myself?
Once, yes. If the code returns, a part or setting needs attention. Repeated resetting does not solve the cause.
My heat pump shows a water pressure code. Can I top it up myself?
Usually, if your system has a filling loop and your manual allows it. Bring it to the pressure stated in the manual and bleed the radiators or circuits if there is air.
Why does my hybrid heat pump show a boiler fault?
In a hybrid set-up the heat pump controller also reports faults of the gas boiler. Intergas, for example, uses F051 for a fault in the boiler. Look up that code on the boiler's own code page.
Which codes need a technician straight away?
Codes about refrigerant pressure, refrigerant charge or compressor temperature. These belong with an F-gas certified technician.
Sources
- Instalpunt fault code database, heat pump section: brand pages and code pages for Vaillant, Remeha, NIBE, Itho Daalderop, ATAG, Atlantic, Intergas and Inventum (as published on 29 November 2026)
- European Commission, F-gas legislation (Regulation (EU) 2024/573, applies since 11 March 2024): climate.ec.europa.eu