Intergas fault code 22
Fault code 22 on an Intergas boiler (including Kombi Kompakt and Kompakt Solo) means: Sensor fault S2. Reset the appliance once. If the code comes back, a part is usually faulty, often a temperature sensor. You can check the water pressure and settings yourself; leave work on gas-carrying parts to a certified gas engineer.
After a safety alert (gas, flue gas, combustion), reset no more than once and call in a certified gas engineer. If you smell gas, call your national gas emergency number or 112 immediately.
Cause
Fault code 22 on an Intergas boiler indicates: Sensor fault S2.
Applies to
Intergas Kombi Kompakt, Kompakt Solo, HRE 12, HRE 18, HRE 24, HRE 24/18, HRE 28/24, HRE 30, HRE 36/30, HRE 36/48.
Matching parts
Intergas parts are available from Instalpunt; shipping to EU countries from €12.95 (€16.95 for more distant countries), usually 3–5 working days.
Parts per Intergas-series: Kombi Kompakt HRE · Kombi Kompakt HReco · Kombi Kompakt HR · Xtreme · Xtend · Prestige.
Based on the cause, these original Intergas parts fit (always check the type number of your appliance):
- Intergas retaining spring NTC heat exchanger for Kombi Kompakt HRE and Kombi Kompakt HR etc. € 7.23
- Intergas NTC for heat exchanger KK (Kombi Kompakt HRE and Kombi Kompakt HR etc.) € 18.67
- Intergas retaining spring pressure sensor for Kombi Kompakt HRE and Xtreme etc. € 7.23
Further reading on this cause
Other Intergas codes with the same cause
- 0 — Sensor fault after self-check
- 0 / 1 — Flow sensor error S1
- 0 / 2 — Return sensor error S2
- 0 / 3 — Hot water sensor error S3
- 0 / 4 — Cylinder sensor error S4
- 10 — Sensor fault S1
Fix it yourself or call an engineer?
Always consult the manual for your appliance and work safely. If in doubt or if the fault comes back, call in a qualified professional. A question about a part? Write to us at info@instalpunt.nl.
Frequently asked questions
What does Intergas boiler fault code 22 mean?
Sensor fault S2.
How do I fix fault code 22 on an Intergas boiler?
First check the cause described above. Then restart the appliance using the reset button. If the message comes back, a part usually needs replacing or the fault needs to be repaired by a qualified professional.
Which parts do I need for Intergas fault code 22?
That depends on the exact cause. In the Intergas parts overview at Instalpunt you will find the current price and stock for each part.
Can I fix fault code 22 myself?
You can reset the appliance and check things like the water pressure or settings yourself. Work on gas-carrying parts must be left to a certified gas engineer.
All Intergas boiler faults and codes at a glance →