Spare parts — usually 3–7 working days EU delivery from € 9.95 · free from € 199 In stock: delivered in 3–5 working days Delivery across the EU WebwinkelKeur 8,8/10 Pay by card, Apple Pay, Pay by Bank, PayPal & Klarna
★★★★★8,8/1024 reviews · verified by WebwinkelKeurAll reviews →
Boiler with display and pressure gauge
Boiler fault codes

Vaillant boiler faults: fault codes, causes and parts (page 2 of 2)

Codes 151 to 228 of the 228 fault codes for Vaillant. Looking for a specific code? Use the search on the first page.

Vaillant boiler fault codes 151 to 228 of 228

The code list is split over 2 pages. Looking for a specific code? Use the search on the first page: it searches all 228 codes in one go.

CodeCause
F.49eBUS undervoltage
F.49eBUS fault
F.52Mass flow sensor connection fault
F.53Mass flow sensor fault
F.54Gas pressure error in combination with F.28/F.29
F.54Gas pressure error
F.56Mass flow sensor control fault
F.57No or too low gas inlet pressure,
F.57Fault in the flue gas path
F.60Electronics error
F.60 - F.67Electronics defective
F.60 - F.69Fault in the electronic controller
F.61Gas valve unit defective
F.61Gas valve control error
F.61Gas valve actuation contains faults
F.62Gas valve unit defective (gas solenoid valves do not close properly). Gas valve unit defective. Main PCB defective.
F.62Gas valve switch-off delay does not work properly
F.62Gas valve switch-off delay error
F.63EEPROM defective
F.63EEPROM error
F.63EEPROM does not work properly
F.64Flow-return sensor electronics measurement error
F.64Fault in electronics/sensor
F.64Electronics/NTC fault
F.65Temperature in main PCB too high
F.65Electronics temperature fault
F.65Electronics temperature too high
F.66Electronics error
F.67Ionisation input signal is outside the limits of 0-5 V
F.67Electronics/flame error
F.67Flame monitoring input signal is outside the limits (0 or 5V)
F.68Fluctuations in the ionisation signal
F.70Communication fault between the display and the PCB
F.70Invalid appliance ID (DSN)
F.70No valid appliance variant for display and/or electronics
F.707No communication between display and PCB
F.71Flow sensor measures a constant value. Flow sensor defective.
F.71Flow sensor reports a constant value
F.71Flow temperature sensor error
F.72Error message from flow sensor and/or return sensor
F.72Flow sensor and/or return sensor fault
F.73Pressure sensor open circuit. Pressure sensor wiring harness interrupted. Pressure sensor defective.
F.73Water pressure sensor fault
F.73Water pressure sensor error
F.73Water pressure sensor signal in the wrong range (too low)
F.74Pressure sensor short circuit
F.74Water pressure sensor signal in the wrong range (too high)
F.74Water pressure sensor error
F.75No pressure jump is measured when the pump is switched on
F.75Error: no pressure jump detection when the pump starts
F.75No pressure jump was detected when the pump was switched on
F.76Thermal fuse on the primary heat exchanger has tripped
F.76Open circuit in wiring harness
F.76Overheating protection on the primary heat exchanger has been activated
F.77Problems with gas valve. Gas valve defective. Wiring harness defective. Main PCB defective.
F.77Flue gas damper fault
F.77Condensate pump or confirmation signal of fittings module central heating
F.77Condensate pump or confirmation signal of fittings module central heating
F.78Open circuit of hot water outlet sensor at the external controller
F.78Wrong control module connected
F.80Open circuit or short circuit of inlet sensor of secondary heat exchanger
F.81actoSTOR charging pump defective;
F.82Protective anode error actoSTOR K300
F.83Boiling dry fault
F.84Flow and return sensors swapped
F.85Flow and return sensors fitted on the same pipe
F.86Underfloor heating contact error
F.87Ignition transformer open circuit
F.88Gas valve fault
F.89Pump error
F.90Communication with the internal cylinder has been interrupted
F.905Communication with CIM module has been interrupted
F.92Gas coding resistor error
F.93Gas group error
F.95Gas group error
F.96Gas group error
Emergency mode “Speed”No speed signal from fan
conNo communication with the PCB