NIBE alarm code 362

In brief

Alarm code 362 on a NIBE heat pump (including F-series) means: Sensor error EP22-BT3: Sensor not connected or defective (flow sensor, climate system 3). Reset the appliance once. If the code comes back, a part is usually faulty, often a temperature sensor. You can check the water pressure and settings yourself; leave work on gas-carrying parts to a certified gas engineer.

After a safety alert (gas, flue gas, combustion), reset no more than once and call in a certified gas engineer. If you smell gas, call your national gas emergency number or 112 immediately.

Cause

Fault code 362 on a NIBE heat pump indicates: Sensor error EP22-BT3: Sensor not connected or defective (flow sensor, climate system 3).

Fixing fault code 362: step by step

  1. Reset the appliance once; a one-off measuring error will then clear.
  2. Where you can reach it without opening the sealed combustion section, check that the sensor plug is seated firmly and the wiring is undamaged.
  3. If the code comes back, the sensor or its wiring is usually faulty (short or open circuit). Sensors in the sealed combustion section should be replaced by a qualified heating engineer.

Applies to

NIBE F-series, -.

Matching parts

NIBE parts are available from Instalpunt; shipping to EU countries from €12.95 (€16.95 for more distant countries), usually 3–5 working days.

Based on the cause, these original NIBE parts fit (always check the type number of your appliance):

All NIBE parts →

Further reading on this cause

Other NIBE codes with the same cause

  • 1 — Sensor error BT1 (outdoor sensor): Sensor not connected or defective
  • 101 — Sensor error BT1 (outdoor sensor): Sensor not connected or defective
  • 102 — Sensor error BT2: No sensor value temporarily available
  • 103 — Sensor error BT3 (heat pump return): Sensor not connected or defective (return sensor)
  • 104 — Sensor error BT4: No sensor value temporarily available
  • 106 — Sensor error BT6: No sensor value temporarily available

Fix it yourself or call an engineer?

Always consult the manual for your appliance and work safely. If in doubt or if the fault comes back, call in a qualified professional. A question about a part? Write to us at info@instalpunt.nl.

Frequently asked questions

What does NIBE heat pump alarm code 362 mean?

Sensor error EP22-BT3: Sensor not connected or defective (flow sensor, climate system 3).

How do I fix alarm code 362 on a NIBE heat pump?

First check the cause described above. Then restart the appliance using the reset button. If the message comes back, a part usually needs replacing or the fault needs to be repaired by a qualified professional.

Which parts do I need for NIBE alarm code 362?

That depends on the exact cause. In the NIBE parts overview at Instalpunt you will find the current price and stock for each part.

Can I fix fault code 362 myself?

You can reset the appliance and check things like the water pressure or settings yourself. Work on gas-carrying parts must be left to a certified gas engineer.