Unico Next 12 HP EVANX through-the-wall air conditioner with electric back-up heating
At a glance
For the coldest days the Unico Next 12 HP EVANX has an electric heating element in the cabinet alongside the heat pump. Below the set switch-over point, which leaves the factory at an outdoor temperature of 4 °C, the element takes over the heating from the heat pump automatically. Nominal output is 2.6 kW in cooling and 2.4 kW in heating.
How you use it
The EVANX is the version for situations where the unit must be able to heat at low outdoor temperatures as well, while the outer wall stays free of an outdoor unit; outside, only the two wall openings show. The inverter-driven Twin Rotary compressor is matched to the electronics for a low noise level and covers 1.5 to 3.1 kW in cooling and 1.2 to 2.7 kW in heat pump heating. The element modulates at 1.5, 1.75 or 2.0 kW, depending on the fan speed you choose. The unit cools, heats, dehumidifies and ventilates, with the settings Auto, Eco and Silent and a timer, all on a display with touch keys. In Silent Mode the indoor sound pressure is 30 dB(A) and the cooling capacity is 2.2 kW. An electrostatic filter and an activated carbon filter are fitted. Business buyers will note the volt-free contact, the RS485 port for Modbus RTU, a cabinet laid out for easy maintenance and fully recyclable packaging.
Specifications
| Product code | 02577 |
|---|---|
| Cooling capacity (nominal) | 2.6 kW |
| Heating capacity (nominal) | 2.4 kW |
| Electric heating element | 1.5 / 1.75 / 2.0 kW |
| Energy class, cooling / heating | A / A |
| EER / COP | 2.6 / 3.1 |
| Power input, cooling / heating (nominal) | 1.0 kW / 0.8 kW |
| Indoor airflow (min / middle / max) | 210 / 270 / 410 m³/h |
| Sound pressure indoors (min to max) | 26 to 42 dB(A) |
| Refrigerant | R32, 0.28 kg (GWP 675) |
| Wall openings | 2 x diameter 202 mm (162 mm possible when replacing) |
| Connection | 230 V, 50 Hz, cable 3 x 1.5 mm² |
| Dimensions (w x h x d) | 1,015 x 540 x 180 mm |
| Weight | 41 kg |
Before you buy
- Allow for the consumption of the element in the electrical connection: up to 2.0 kW and 8.4 A.
- Two ducts through the exterior wall are needed, 202 mm as standard. The wall may be up to 1 metre thick.
- A condensate drain is mandatory for heating. The unit is fitted and set up by an installer, and that includes the switch-over point of the element.
Manual and documents
The manufacturer's manual and product sheet are on our specialist site olimpia-air.com (site in Dutch): documents for the Unico Next EVANX.




Reviews