Eco Heating Systems spare parts
Original parts for all Eco Heating Systems appliances. Choose your model below for the complete parts list (often with an exploded view) and order directly.
Instalpunt supplies 507 original Eco Heating Systems parts for 41 models, with part number, price and exploded view. Order online.
- 507Spare parts
- 41Models
- €0.24From
→ View the complete Eco Heating Systems brand page with appliances, hot water cylinders and buying advice.
Eco Heating Systems parts by type
Looking for a specific type of part? For each type, all Eco Heating Systems spare parts are listed with price, stock and the models they fit.
- Fans 9
- Sensors 7
- Pressure switches and differential pressure switches 6
- Heat exchangers 29
- Gas valves and gas control 14
- Burner control units 20
- Ignition and ionisation 9
- Siphons and condensate drains 10
- Burners 16
- Maintenance and service kits 7
- Valves 12
- Gaskets and seals 64
- Pipes, tubes and hoses 71
- Casing and panels 34
- Insulation 9
- Fixing material 33
Eco Heating Systems boilers
- Ambassador 914 100 (serial no. 000-112)39 parts
- Ambassador 914 120 (serial no. 000-113)39 parts
- Ambassador 914 150 (serial no. 000-114)40 parts
- Ambassador 914 180 (serial no. 000-115)38 parts
- Ambassador 914 60 (serial no. 000-100)37 parts
- Ambassador 914 80 (serial no. 000-111)40 parts
- Ambassador SB 120 (serial no. 000-413)58 parts
- Ambassador+ 100 (serial no. 000-212)68 parts
- Ambassador+ 120 (serial no. 000-213)69 parts
- Ambassador+ 150 (serial no. 000-214)66 parts
- Ambassador+ 180 (serial no. 000-215)65 parts
- Ambassador+ 60 (serial no. 000-200)68 parts
- Ambassador+ 80 (serial no. 000-211)65 parts
- CB CH 105 (serial no. 0-500012)100 parts
- CB CH 125 (serial no. 0-500013)99 parts
- CB CH 155 (serial no. 0-500014)99 parts
- CB CH 85 (serial no. 0-500011)100 parts
- Senator 400 (serial no. 000-157)43 parts
- Senator 550 (serial no. 000-158)42 parts
- Senator+ 400 (serial no. 000-257)80 parts
- Senator+ 550 (serial no. 000-258)80 parts
Eco Heating Systems domestic hot water boilers
- CB HW 105 (serial no. 0-505012)102 parts
- CB HW 125 (serial no. 0-505013)102 parts
- CB HW 155 (serial no. 0-505014)101 parts
- CB HW 85 (serial no. 0-505011)102 parts
- CD 100 (serial no. 000-117)40 parts
- CD 120 (serial no. 000-118)40 parts
- CD 150 (serial no. 000-119)40 parts
- CD 180 (serial no. 000-120)40 parts
- CD 80 (serial no. 000-116)43 parts
- CD+ 100 (serial no. 000-217)57 parts
- CD+ 120 (serial no. 000-218)57 parts
- CD+ 150 (serial no. 000-219)55 parts
- CD+ 180 (serial no. 000-220)55 parts
- CD+ 80 (serial no. 000-216)55 parts
- Consul 35/230 (serial no. 000-163)46 parts
- Consul 55/230 (serial no. 000-164)46 parts
- Consul+ 35 (serial no. 000-260)46 parts
- Consul+ 35/230 (serial no. 000-263)9 parts
- Consul+ 55 (serial no. 000-261)46 parts
- Consul+ 55/230 (serial no. 000-264)9 parts
Eco Heating Systems fault code? This is the part you usually need
Your Eco Heating Systems appliance is showing a fault code? Below you can see, for common codes, which part is usually the cause – ready to order.
| Fault code | What is going on | Part |
|---|---|---|
| 1 | No gas, incorrectly adjusted gas valve. | View gas valves |
| 2 | Short circuit in the gas valve coil, water on wiring or gas valve. | View gas valves |
| 3 | Short circuit in the gas valve coil, water on wiring or gas valve. | View gas valves |
| 5 | Electrical wiring not connected correctly or fan not working properly. | View fans |
| 6 | Electrical wiring not connected correctly or fan not working properly. | View fans |
| 7 | Electrical wiring not connected correctly, or fan not working properly. | View fans |
| 14 | No air transport to the burner; flue or air inlet blocked, or APS defective, or air signal hose not connected to the air inlet pipe, or water in the hose. | View burners |
| 15 | Burner door clixon activated by overheating of the burner door or restricted water flow through the heat exchanger, or the rear wall thermal fuse has been activated because the rear wall insulation disc (combustion chamber) is damaged or broken. | View heat exchangers |
| 16 | There is no water in the heat exchanger, or the flue gas sensor is not working, or the heat exchanger is overheated. | View heat exchangers |
| 22 | Poor gas supply, or O2 level in flue gas incorrect, or poor ignition electrode. | View electrodes |
| 32 | Insufficient water flow through the heat exchanger. | View heat exchangers |
| 33 | There is no water in the heat exchanger or it is not electrically connected. | View heat exchangers |
| 34 | There is no water in the heat exchanger or it is not electrically connected. | View heat exchangers |
| 35 | No air transport to the burner after heat demand; flue or air inlet blocked, or APS defective, or air signal hose not connected to the air inlet pipe, or water in the hose. | View burners |
| 105 | Too little water through the heat exchanger. | View heat exchangers |
| 122 | Hot water sensor defective or not connected. | View sensors |
| 129 | Faulty DHW sensor or short circuit. | View sensors |
| 164 | Not enough water is flowing through the heat exchanger. | View heat exchangers |
| 168 | Flue-side blockage of the heat exchanger. | View heat exchangers |
For guidance only: the same code can have a different cause depending on the model. Not sure? Write to us or have the appliance checked by a qualified professional.