Spare parts — usually 3–7 working days EU delivery from € 9.95 · free from € 199 In stock: delivered in 3–5 working days Delivery across the EU WebwinkelKeur 8,8/10 Pay by card, Apple Pay, Pay by Bank, PayPal & Klarna
★★★★★8,8/1024 reviews · verified by WebwinkelKeurAll reviews →
ATAG heat pump error codes – Heat pump outdoor unit
Heat pump fault codes

ATAG heat pump faults: fault codes, causes and parts

All 99 fault codes for ATAG heat pumps, plus the faults that show no code. Type your code or choose your symptom.

In brief

A fault on an ATAG heat pump usually means that the appliance has locked out or is reporting a fault code. Note the code on the display and look it up below: for each code you will find its meaning, checks you can safely do yourself and the parts that are often checked or replaced. Frequently searched: 937 (no circulation), 2P7 (pre-circulation error), 938 (anode error). No code? Check the power supply, the settings and the filters, and reset once. If the fault comes back, call in a qualified professional.

Most searched ATAG faults

These are the codes that visitors to this site search for most often.

See the 25 most searched fault codes of 2026, with the figures behind them →

ATAG heat pump faults without a code on the display

Not every fault shows a code. These are the symptoms we come across most often with ATAG appliances, with what you can check yourself before calling someone out.

Heat pump no longer produces heat

Check that the system has enough pressure and whether there is a message on the display or in the app. After a power cut, some units start up in a safe mode and have to be released manually. View the matching parts → Read also: heat pump freezes or defrosts constantly →

Outdoor unit freezes or defrosts constantly

A thin layer of ice in frosty weather is normal; the unit defrosts itself periodically. If the ice stays or the unit defrosts every few minutes, the airflow is obstructed or something is wrong with the defrost control. View the matching parts → Read also: heat pump freezes or defrosts constantly →

Too little or too cold hot water

Check the set hot water temperature and whether the electric immersion heater is enabled. A sharp drop in hot water capacity often points to a faulty cylinder sensor or a worn anode in the tank. View the matching parts → Read also: replace the anode before the tank fails →

Noise or vibrations

A noticeably louder noise than normal usually comes from the fan or from vibrations carried through the pipework. Check that the unit stands clear and that the anti-vibration mounts are intact. View the matching parts → Read also: noise and ice on the outdoor unit →

All 99 ATAG heat pump fault codes

CodeCause
1TD sensor error
114Outdoor sensor defective
2P2Anti-legionella incomplete
2P2Anti-legionella incomplete (disinfection cycle not completed)
2P3DHW boost: comfort not reached
2P4Electric element thermostat (manual)
2P5Electric element thermostat (auto)
2P7Pre-circulation error
2P8Low pressure warning
2P9SG Ready configuration error
420Bus power supply overload
730Buffer top sensor defective
731Buffer overheating
732Storage tank bottom sensor defective
902Flow sensor damaged
905HP compressor configuration error
906HP fan configuration error
907HP 4-way valve configuration error
908HP expansion valve configuration error
909HP no fan speed
910Inverter communication error - TDM
910Communication error with HP
912HP 4-way valve configuration error
913LWT sensor error
914TR sensor error
917Frost protection error
918Pump defective error
921Electricity/gas cost ratio error
922Frost protection error
923Heating circuit pressure - fault
924HP communication error
925No boiler present
926Low pressure warning
927AUX inputs mismatch error
928Configuration error of energy supply blocking
931Inverter fault Subcode par 13.9.1
931Inverter fault
931-1Subcode par 13.9.1 Compressor ipm current sampling failure
931-10Subcode par 13.9.1 FC HW Overcurrent
931-11Subcode par 13.9.1 PFC SW Overcurrent
931-12Subcode par 13.9.1 FC Overvoltage
931-13Subcode par 13.9.1 A/D Fault
931-14Subcode par 13.9.1 Wrong Addressing
931-15Subcode par 13.9.1 Compressor Speed Less than Zero
931-16Subcode par 13.9.1 Compressor Current No Change
931-16Subcode par 13.9.1 Compressor current no change
931-17Subcode par 13.9.1 Compressor Speed Mismatch vs Calc
931-2Subcode par 13.9.1 Capacitors precharge failure
931-3Subcode par 13.9.1 AC input voltage sampling failure
931-4Subcode par. 13.9.1: heat sink sensor failure
931-5Subcode par 13.9.1 DSP&MCU communication error
931-6Subcode par 13.9.1 AC input over-current
931-7Subcode par 13.9.1 PFC Current Sampling Fault
931-8Subcode par. 13.9.1: FC temperature sensor fault
931-9Subcode par 13.9.1 EPROM Fault
933Flow sensor temperature too high
933Flow sensor temperature too high, main circuit overheating
934DHW tank sensor damaged
934Boiler sensor damaged
935Tank overtemperature
935Boiler overheating
936Floor thermostat 1 error message
937No circulation
938Anode error
940Hydraulic diagram not determined
941HV IN1 not determined
942HV IN2 not determined
944Overtemperature during cooling
945Flow switch is stuck
946HP compressor fault
947HP 4-way valve configuration error
950High TD HARD_STOP
951High temp TD sensor
955Water circulation check error
956Wrong HP Kompressor model
957Wrong HP Fan model
958Buffer overheating
959Buffer sensor high fault
960HP return water temperature
962Defrost energy
968ATGBUS TDM - EM communication error
970Aux incorrect pump configuration
989Machine empty error
997Compressor overloaded
998Compressor overloaded
9E18Safety thermostat ST1 fault
9E21Low refrigerant charge fault
9E22Machine empty error
9E24EXV blocked fault
9E26HW fault in DHW backup interface
9E27DHW cylinder relay stuck
9E28Overpressure protection
9E31Compressor thermostat protection
9E34Low pressure protection
9E36Imbalance in compressor phase current
9E38Excessive variation in compressor current
9E5High pressure switch tripped
9E8Low pressure switch fault with compressor OFF
9E9Klixon fault with compressor OFF

Order parts for your ATAG heat pump

ATAG parts are available from Instalpunt; shipping to EU countries from €12.95 (€16.95 for more distant countries), usually 3–5 working days.

Parts per Atag-series: A Series · i Series (iCon) · Q Series · E Series · P-series (iCon) · Blauwe Engel · XL-series.

View ATAG parts →

Frequently asked questions about ATAG faults

What does a fault on an ATAG heat pump mean?

The appliance is reporting that it has shut itself down or cannot continue. The code on the display points to the group of causes: ignition, water pressure, a sensor, the fan or communication with the thermostat. The table above shows, for each code, what ATAG means by it.

How do I reset my ATAG heat pump?

The reset button is on the control panel of your ATAG heat pump; on most appliances you hold it down for two to five seconds until the display responds. Reset once. If the same fault comes straight back, resetting will not solve it and a part or a setting needs attention. Always consult the manual for your model: the position of the button and how long to press it differ per series.

Can I fix an ATAG fault myself?

You can top up the water pressure, bleed the system, replace filters and clean a siphon yourself. Anything behind the sealed section of a gas appliance is a different matter: work on the gas valve, burner, heat exchanger and flue must be carried out by a certified gas engineer.

How much does it cost to fix a fault?

That depends on the cause and whether a part is needed. With us you can see the part straight away with its price and delivery time, so you know where you stand in advance. If you call in an engineer, always ask about the call-out charge and hourly rate before they come.

Where can I find the right part for my ATAG?

Check the rating plate for the exact type and use it to search our catalogue, or search directly by the manufacturer number of the faulty part. Each part lists the appliances it fits.

Scroll to Top