Atlantic spare parts
Original parts for all Atlantic appliances. Choose your model below for the complete parts list (often with an exploded view) and order directly.
Instalpunt supplies 297 original Atlantic parts for 30 models, with part number, price and exploded view. Order online.
- 297Spare parts
- 30Models
- €2.72From
→ View the complete Atlantic brand page with appliances, hot water cylinders and buying advice.
Atlantic parts by type
Looking for a specific type of part? For each type, all Atlantic spare parts are listed with price, stock and the models they fit.
Atlantic hot water cylinders
Atlantic heat pumps
- Alfea Extensa A.I. 10 R3238 parts
- Alfea Extensa A.I. 5 R3238 parts
- Alfea Extensa A.I. 6-8 R3238 parts
- Alfea Extensa Duo A.I. 10 R3266 parts
- Alfea Extensa Duo A.I. 3 R3266 parts
- Alfea Extensa Duo A.I. 5 R3266 parts
- Alfea Extensa Duo A.I. 6-8 R3266 parts
- Aurea 5 R32 Hybrid Add On28 parts
- Outdoor unit21 parts
- Hydraulic module44 parts
- Loria 6004 R3224 parts
- Loria 6004 R410a28 parts
- Loria 6006 - 6008 R3224 parts
- Loria 6006 - 6008 R410a28 parts
- Loria 6010 R3223 parts
- Loria Duo 6003 R3243 parts
- Loria Duo 6004 R3243 parts
- Loria Duo 6004 R410a52 parts
- Loria Duo 6006 - 6008 R3243 parts
- Loria Duo 6006 - 6008 R410a52 parts
- Loria Duo 6010 R3242 parts
- WOYA 060KLT 6 kW14 parts
- WOYA 060LFC(A) 6 kW21 parts
- WOYA 080KLT 8 kW17 parts
- WOYA 080LFC(A) 8 kW23 parts
- WOYA 100KLT 10 kW20 parts
- WOYA 100LFTA 10 kW20 parts
Atlantic heat pump water heaters
Atlantic fault code? This is the part you usually need
Your Atlantic appliance is showing a fault code? Below you can see, for common codes, which part is usually the cause – ready to order.
| Fault code | What is going on | Part |
|---|---|---|
| 10 | Outdoor temperature sensor: short circuit. Sensor disconnected or switched off. Sensor defective. Other fault. | View sensors |
| 32 | Flow sensor 2: short circuit. Sensor disconnected or switched off. Sensor defective. Other fault. | View sensors |
| 33 | HP flow sensor: short circuit. Sensor disconnected or switched off. Sensor defective. Other fault. | View sensors |
| 44 | HP return sensor: short circuit. Sensor disconnected or switched off. Sensor defective. Other fault. | View sensors |
| 50 | DHW sensor 1: short circuit. Sensor disconnected or switched off. Sensor defective. Other fault. | View sensors |
| 60 | Room sensor 1: short circuit. Sensor disconnected or switched off. Sensor defective. Other fault. | View sensors |
| 62 | Outdoor unit main PCB fault | View PCBs |
| 65 | Room sensor 2: short circuit. Sensor disconnected or switched off. Sensor defective. Other fault. | View sensors |
| 71 | Discharge side temperature sensor fault | View sensors |
| 72 | Compressor temperature sensor fault | View compressors |
| 73 | Evaporator temperature sensor fault (centre) | View sensors |
| 74 | Outdoor temperature sensor fault | View sensors |
| 78 | Expansion valve temperature sensor fault | View sensors |
| 84 | Compressor current fault | View compressors |
| 95 | Compressor rotor position detection fault. Compressor start fault | View compressors |
| 97 | Outdoor unit fan fault | View fans |
| 212 | Internal comms fault: sensor disconnected or switched off. | View sensors |
| 441 | BX31 without function: short circuit. Sensor disconnected or switched off. Sensor defective. Other fault. | View sensors |
| 442 | BX32 without function: short circuit. Sensor disconnected or switched off. Sensor defective. Other fault. | View sensors |
| 443 | BX33 without function: short circuit. Sensor disconnected or switched off. Sensor defective. Other fault. | View sensors |
| 444 | BX34 without function: short circuit. Sensor disconnected or switched off. Sensor defective. Other fault. | View sensors |
| - | PCB (main) | View PCBs |
| A0 | DC voltage fault: fan motor | View fans |
| A0 | DC voltage fault: pump | View circulation pumps |
| A0 | DC voltage fault: PCB | View PCBs |
| A1 | Discharge temperature fault: sensor, discharge temp. | View sensors |
| A2 | Overcurrent protection. DC current detection: PCB. | View PCBs |
| A2 | Overcurrent protection. DC current detection: compressor. | View compressors |
| A3 | PCB | View PCBs |
| A3 | Compressor temperature protection | View compressors |
| A5 | Abnormal compressor rotation: abnormal operation due to too low or too high load. | View compressors |
| A5 | Abnormal compressor rotation: compressor or PCB. | View PCBs |
| A6 | Suction temperature sensor fault. Sensor, suction temp. | View sensors |
| A7 | Defrost temperature sensor fault. Sensor, defrost temp. | View sensors |
| A8 | Discharge temperature sensor fault. Sensor, discharge temp. | View sensors |
| C1 | Upper fan motor for unit 1242XU 1643XU: fuse CF7 (250V T3.15A). Fan motor (*2). PCB. | View fans |
| C2 | Outdoor temperature sensor fault. | View sensors |
| C3 | Fan motor fault for unit 0643XU 1043XU. Lower fan motor fault for unit 1242XU 1643XU: fan motor. | View fans |
| C4 | PCB (main) temperature rise (above 110 °C). Incorrect installation. | View PCBs |
| C5 | Sensor fault on PCB (main). PCB temperature sensor. | View PCBs |
For guidance only: the same code can have a different cause depending on the model. Not sure? Write to us or have the appliance checked by a qualified professional.