Boiler fault codes

ATAG boiler faults: fault codes, causes and parts

All 234 fault codes for ATAG boilers, plus the faults that show no code. Type your code or choose your symptom.

In brief

A fault on an ATAG boiler usually means that the appliance has locked out or is reporting a fault code. Note the code on the display and look it up below: for each code you will find its meaning, checks you can safely do yourself and the parts that are often checked or replaced. Frequently searched: C1 18 (pressure too low (), C1 33 (no flame after 5 ignition attempts), 140* (dynamic pressure increase failed 2x (no pump…). No code? Check the water pressure (1.5 to 2 bar when cold), the power supply and the gas tap, and reset once. If the fault comes back, call in a certified gas engineer. If you smell gas, call your national gas emergency number or 112 immediately.

Most searched ATAG faults

These are the codes that visitors to this site search for most often.

See the 25 most searched fault codes of 2026, with the figures behind them →

ATAG boiler faults without a code on the display

Not every fault shows a code. These are the symptoms we come across most often with ATAG appliances, with what you can check yourself before calling someone out.

No hot water, but the heating works

The boiler heats the radiators but not the tap water. Check that the hot water function is switched on in the display (on some appliances it is called DHW mode or summer mode) and that the hot water valve under the boiler is open. If the water stays cold, this usually points to a fouled or leaking DHW heat exchanger, a faulty diverter valve or a DHW sensor giving incorrect readings. View the matching parts → Read the full explanation: no hot water, six causes →

Water pressure keeps dropping

Top up to 1.5–2 bar when cold and bleed the radiators. If the pressure drops again within a few days, the expansion vessel has often lost its pre-charge or there is a small leak in the system. A pressure relief valve that keeps dripping gives the same symptom. View the matching parts → Read the full explanation: water pressure keeps dropping – expansion vessel or leak? →

Boiler shuts down and locks out

The appliance shuts down and only starts again after a reset. Reset once; if the fault comes straight back, leave the reset button alone. Repeatedly resetting a locked-out boiler is not without risk: the safety device trips for a reason. View the matching parts → Read also: is the boiler cutting out because of a sensor or overheating? →

Radiators stay cold

Check that the thermostat is calling for heat, that the radiator valves are open and that the system has enough pressure. If everything stays cold while the boiler is firing, the circulation pump is often not running or the diverter valve is stuck in the hot water position. View the matching parts → Read the full explanation: radiators stay cold →

Ticking, humming or boiling noise

A banging noise at start-up usually points to air or limescale in the heat exchanger. A humming pump may have a worn bearing. A rattling fan is often rubbing or dirty. View the matching parts → Read also: replacing the fan – what to rule out first →

Water under the boiler

Check where it is coming from: the condensate drain (siphon blocked or cracked), the pressure relief valve (pressure too high or faulty expansion vessel) or a fitting. If in doubt, switch the boiler off and close the water supply. View the matching parts → Read the full explanation: water under the boiler – condensate or a leak? →

ATAG boiler fault codes 1 to 150 of 234

The code list is split over 2 pages. Looking for a specific code? Use the search at the top of this page: it searches all 234 codes in one go.

CodeCause
10Outdoor sensor fault (e.g. open, short-circuited, out of range)
101Maximum temperature exceeded
101Overheating
102Pressure sensor fault
102Pressure sensor defective
104No pump kick
104Insufficient flow rate
105No fault; air purge programme active (approx. 7 minutes)
108Pressure < Pmin (< 0.7 bar), system must be topped up
108Pressure too low (<0.7 bar) or pump pressure increase too low (no pump detection)
109Pressure too high (>3 bar) or pump pressure increase too high
109Pressure too high (>Pmax)
110Flow sensor fault (e.g. open, short-circuited, out of range)
110Safety temperature exceeded
110Flow sensor fault (e.g. open, short-circuited, out of range)
111Maximum temperature exceeded
112Return sensor fault (e.g. open, short-circuited, out of range)
112Return sensor fault (e.g. open, short-circuited, out of range)
114Outdoor sensor fault (e.g. open, short-circuited, out of range)
114Outdoor sensor fault (e.g. open, short-circuited, out of range)
117Pressure too high (>3 bar) or pump pressure increase too high
118Pressure too low (<0.7 bar) or pump pressure increase too low (no pump detection)
119Link between positions 4 and 5 of X2 missing/open circuit
129Fan fault (fan does not start)
133No flame after 5 ignition attempts
140*Dynamic pressure increase failed 2x (no pump detection)
151Fan fault (speed control not achieved or out of range) or defective control unit.
154Flow temperature rising too quickly, dT too large, return > flow
180No fault: briefly displayed when exiting chimney sweep function
181No fault: briefly displayed when exiting 'accelerator pedal function'
197Link at 'external safety contact' position missing/open circuit
1P4Pressure < Pmin (0.7 - 1.0 bar), system must be topped up
1P4Pressure between 0.7 and 1 bar, top up to above 1.3 bar
1P9Dynamic pressure increase failed 1x
20Coding plug not recognised.
20Internal data fault
20Flow temperature sensor defective
20Domestic hot water temperature sensor incorrectly fitted
20Gas valve assembly defective
20Temperature monitor TB1 faulty External monitor has tripped. Temperature monitor locked out.
20Outdoor temperature sensor not recognised.
201Domestic hot water sensor defective (Combi)
201Domestic hot water sensor fault (e.g. open, short-circuited, out of range)
203Cylinder sensor - open circuit (Solo)
303PCB fault
303Control unit fault
304Too many resets (5x in 15 minutes)
304Too many resets
40Temperature exceeded at the burner flow temperature sensor.
40Open circuit or short circuit of the burner flow temperature sensor.
40Internal fault
40Internal data fault
40Boiler block temperature limiter has been activated
40Flame is detected although the appliance is switched off
40Flame is not detected
50Domestic hot water sensor fault (e.g. open, short-circuited, out of range)
50Gradient limitation: temperature rising too quickly
50After gas shut-off: flame is detected.
50Reset button was pressed accidentally.
501No flame detected
501Ionisation fault
61No communication via Zbus
612Fan fault (fan does not start)
78Water pressure sensor out of range or not connected or, if water pressure OK: pump defective.
B0Flow water temperature rising too quickly
B0Flow water temperature rising too quickly No or insufficient flow in the system?
B1Temperature difference between flow and return too large Insufficient flow or pump faulty?
B1Temperature difference between flow and return too large
B3Maximum flue gas temperature exceeded (if flue gas sensor fitted)
B3Maximum flue gas temperature exceeded (if flue gas sensor fitted) Blockage in the flue gas outlet?
B4Maximum flow water temperature exceeded No flow or too much resistance in the system?
B4Maximum flow water temperature exceeded
B5Maximum flow water temperature exceeded
B5Maximum return water temperature exceeded No flow or too much resistance in the system?
B6Return temperature higher than flow temperature Circulation pump fitted the wrong way round?
B6Maximum flow water temperature exceeded
B7General lockout input open
B7General lockout input open Water pressure too low or low water pressure protection faulty?
BL 01External safety contact open
BL 01External safety contact open. External safety contact (pos. 24 and 25) is active
BL 11Maximum Delta-T of flow and return sensor on central heating (CH) repeatedly exceeded Domestic hot water operation is still possible as normal during the lockout. During the lockout the pump continues to run at minimum capacity
BL 11Maximum temperature difference of flow and return sensor on CH repeatedly exceeded. Domestic hot water operation is normally possible during the lockout (LO). During the LO the pump continues to run at minimum capacity
BL 11Maximum temperature difference of flow and return sensor on CH repeatedly exceeded. Domestic hot water operation is normally possible during the lockout (LO). During the LO the pump continues to run at minimum capacity.
BL 11Maximum temperature difference of flow and return sensor on CH repeatedly exceeded. Domestic hot water operation is normally possible during the lockout (LO). During the LO the pump continues to run at minimum capacity.
BL 11Maximum temperature difference of flow and return sensor on CH repeatedly exceeded.
BL 12Maximum Delta-T of flow and return sensor on domestic hot water (DHW) repeatedly exceeded Central heating system operation is still possible as normal during the lockout. During the lockout the pump continues to run at minimum capacity.
BL 12Maximum temperature difference of flow and return sensor on DHW repeatedly exceeded. CH operation is normally possible during the lockout (LO). During the LO the pump continues to run at minimum capacity
BL 12Maximum temperature difference of flow and return sensor on DHW repeatedly exceeded. CH operation is normally possible during the lockout (LO). During the LO the pump continues to run at minimum capacity.
BL 60Incorrect parameter setting of the minimum or maximum output
BL 67A Delta-T has been detected between flow and return sensor while the burner is not operating Once the Delta-T has disappeared the lockout will be cleared
BL 67A temperature difference has been detected between flow and return sensor while the burner is not operating. Once the temperature difference has disappeared, the lockout (LO) will be cleared
BL 67A temperature difference has been detected between flow and return sensor while the burner is not operating. Once the temperature difference has disappeared, the lockout (LO) will be cleared.
BL 80Maximum flue gas temperature exceeded (if flue gas sensor fitted) The lockout (BL) is only cleared once the flue gas temperature falls below the maximum flue gas temperature
BL 80Maximum flue gas temperature exceeded (if flue gas sensor fitted) The lockout is only cleared once the flue gas temperature falls below the maximum flue gas temperature
BL 80Maximum flue gas temperature exceeded (if flue gas sensor fitted). The lockout (LO) is only cleared once the flue gas temperature falls below the maximum flue gas temperature.
BL 80Maximum flue gas temperature exceeded (if flue gas sensor fitted). The lockout (LO) is only cleared once the flue gas temperature falls below the maximum flue gas temperature.
BL 80Maximum flue gas temperature exceeded (if flue gas sensor fitted) The lockout is only cleared once the flue gas temperature falls below the maximum flue gas temperature
BL 81Flue gas sensor open circuit after having previously been connected to the controller Burner is locked out until the flue gas sensor is reconnected
BL 81Flue gas sensor open circuit after having previously been connected to the controller Burner is locked out until the flue gas sensor is reconnected
BL 81Flue gas sensor open circuit after having been connected to the controller. Burner is locked out until the flue gas sensor is reconnected.
BL 82Flue gas sensor short-circuited, heat demand blocked and pump capacity at minimum
BL 84Flue gas sensor short-circuited, heat demand blocked and pump capacity at minimum
BL 85The controller has detected no water flow. Automatic air purge cycle is started. If water flow is detected during this cycle, the air purge cycle is ended and the burner is enabled.
BL 85The controller has detected no water flow Automatic venting cycle is started. If water flow is detected during this cycle, the venting cycle is ended and the burner is enabled.
BL 85The controller has detected no water flow
BL 85The controller has detected no water flow. Automatic air purge cycle is started.
BL 86Mains frequency deviates by more than 2.5 Hz the mains frequency deviates by more than 2.5 Hz from the standard 50 Hz (<47.5 Hz, >52.5 Hz)
BL 86Mains frequency deviates by more than 2.5 Hz from the standard 50 Hz (<47.5 Hz and > 52.5 Hz)
Bx01sc01Fan is not running at the correct speed
Bx03sc01Flow sensor T1 open.
Bx03sc02Flow temperature T1 too high.
Bx05sc01Return sensor T2 open.
Bx05sc02Return temperature T2 too high.
Bx08sc01Safety contact open.
Bx12sc01Water pressure sensor open.
Bx12sc02Water pressure sensor short-circuited.
Bx12sc03Water pressure lower than 0.7 bar. Top up.
Bx12sc04Water pressure too high. Reduce pressure.
Bx12sc05No pressure increase at pump start.
Bx13sc01Temperature difference between T1 and T2 too high.
Bx15sc01Communication error between boilers.
C 10Outdoor sensor fault (e.g. open, short-circuited, out of range)
C 20flow sensor fault (e.g. open, short-circuited, out of range)
C 20Flow sensor fault
C 20Flow sensor fault (e.g. open, short-circuited, out of range)
C 20Flow sensor fault e.g. open, short-circuited, out of range.
C 40return sensor fault (e.g. open, short-circuited, out of range)
C 40Return sensor fault
C 50Domestic hot water sensor fault (e.g. open, short-circuited, out of range)
C 50Wiring fault.
C 61No communication via Z-bus (reset only possible by interrupting the power supply)
C 61OpenTherm room thermostat fault.
C 62Unknown OpenTherm room thermostat.
C 78Water pressure sensor fault
C 78Water pressure sensor out of range or not connected or, if water pressure OK: pump defective
C 78Water pressure sensor out of range or not connected or, if water pressure OK: pump defective.
C1 05Air purge programme active
C1 05Air purge programme active
C1 10safety temperature exceeded
C1 11maximum temperature exceeded
C1 17Water pressure too high (>3 bar)
C1 17pressure too high (>3 bar) or pump pressure increase too high
C1 18Pressure too low (<0.7 bar) or pump pressure increase too low (no pump detection)
C1 18Water pressure too low (<1.0 bar or <0.7 bar)
C1 29Fan fault, fan does not start
C1 29fan fault (fan does not start)
C1 33no flame after 5 ignition attempts
C1 51Fan fault (speed control not achieved or out of range)
C1 52Outdoor sensor setting incorrect. Parameter 555 b0 and/or b1 is incorrectly set to 'on'
C1 54Flow rising too quickly, delta T too large, return > flow

Order parts for your ATAG boiler

ATAG parts are available from Instalpunt; shipping to EU countries from €12.95 (€16.95 for more distant countries), usually 3–5 working days.

Parts per Atag-series: A Series · i Series (iCon) · Q Series · E Series · P-series (iCon) · Blauwe Engel · XL-series.

View ATAG parts →

Frequently asked questions about ATAG faults

What does a fault on an ATAG boiler mean?

The appliance is reporting that it has shut itself down or cannot continue. The code on the display points to the group of causes: ignition, water pressure, a sensor, the fan or communication with the thermostat. The table above shows, for each code, what ATAG means by it.

How do I reset my ATAG boiler?

The reset button is on the control panel of your ATAG boiler; on most appliances you hold it down for two to five seconds until the display responds. Reset once. If the same fault comes straight back, resetting will not solve it and a part or a setting needs attention. Always consult the manual for your model: the position of the button and how long to press it differ per series.

Can I fix an ATAG fault myself?

You can top up the water pressure, bleed the system, replace filters and clean a siphon yourself. Anything behind the sealed section of a gas appliance is a different matter: work on the gas valve, burner, heat exchanger and flue must be carried out by a certified gas engineer.

How much does it cost to fix a fault?

That depends on the cause and whether a part is needed. With us you can see the part straight away with its price and delivery time, so you know where you stand in advance. If you call in an engineer, always ask about the call-out charge and hourly rate before they come.

Where can I find the right part for my ATAG?