Boiler with display and pressure gauge
Boiler fault codes

AWB boiler faults: fault codes, causes and parts

All 436 fault codes for AWB boilers, plus the faults that show no code. Type your code or choose your symptom.

In brief

A fault on an AWB boiler usually means that the appliance has locked out or is reporting a fault code. Note the code on the display and look it up below: for each code you will find its meaning, checks you can safely do yourself and the parts that are often checked or replaced. Frequently searched: 24 (return temperature > 90°C), E (pump control circuit fault), 3.1 (flow NTC short-circuited). No code? Check the water pressure (1.5 to 2 bar when cold), the power supply and the gas tap, and reset once. If the fault comes back, call in a certified gas engineer. If you smell gas, call your national gas emergency number or 112 immediately.

Most searched AWB faults

These are the codes that visitors to this site search for most often.

See the 25 most searched fault codes of 2026, with the figures behind them →

AWB boiler faults without a code on the display

Not every fault shows a code. These are the symptoms we come across most often with AWB appliances, with what you can check yourself before calling someone out.

No hot water, but the heating works

The boiler heats the radiators but not the tap water. Check that the hot water function is switched on in the display (on some appliances it is called DHW mode or summer mode) and that the hot water valve under the boiler is open. If the water stays cold, this usually points to a fouled or leaking DHW heat exchanger, a faulty diverter valve or a DHW sensor giving incorrect readings. View the matching parts → Read the full explanation: no hot water, six causes →

Water pressure keeps dropping

Top up to 1.5–2 bar when cold and bleed the radiators. If the pressure drops again within a few days, the expansion vessel has often lost its pre-charge or there is a small leak in the system. A pressure relief valve that keeps dripping gives the same symptom. View the matching parts → Read the full explanation: water pressure keeps dropping – expansion vessel or leak? →

Boiler shuts down and locks out

The appliance shuts down and only starts again after a reset. Reset once; if the fault comes straight back, leave the reset button alone. Repeatedly resetting a locked-out boiler is not without risk: the safety device trips for a reason. View the matching parts → Read also: is the boiler cutting out because of a sensor or overheating? →

Radiators stay cold

Check that the thermostat is calling for heat, that the radiator valves are open and that the system has enough pressure. If everything stays cold while the boiler is firing, the circulation pump is often not running or the diverter valve is stuck in the hot water position. View the matching parts → Read the full explanation: radiators stay cold →

Ticking, humming or boiling noise

A banging noise at start-up usually points to air or limescale in the heat exchanger. A humming pump may have a worn bearing. A rattling fan is often rubbing or dirty. View the matching parts → Read also: replacing the fan – what to rule out first →

Water under the boiler

Check where it is coming from: the condensate drain (siphon blocked or cracked), the pressure relief valve (pressure too high or faulty expansion vessel) or a fitting. If in doubt, switch the boiler off and close the water supply. View the matching parts → Read the full explanation: water under the boiler – condensate or a leak? →

AWB boiler fault codes 1 to 150 of 436

The code list is split over 3 pages. Looking for a specific code? Use the search at the top of this page: it searches all 436 codes in one go.

CodeCause
---User interface fault
---Waiting time after DHW demand (2 min.)
0Flame present when it should not be
0Standby
0.0Ionisation fault in standby.
0.1Short circuit in 24 V circuit.
0.2Ionisation fault during operation
0.3Internal fault mcba.
0.4Internal fault mcba.
0.5Internal fault mcba.
0.6See fault 05.
0.7See fault 03.
0.8Air pressure switch does not close.
0.9See fault 05.
00No fault
01Ignition fault
02Fan fault
03Repeated air fault: fan keeps running below the start speed.
03No tacho signal
04Ignition fault
04See F 01
05Maximum limit fault, flow temperature too high
06Flow NTC fault. NTC is broken or wiring faulty. Check wiring or replace NTC.
07DHW NTC fault. NTC is broken or wiring faulty. Check wiring or replace NTC.
08Cylinder NTC fault
09Water pressure sensor broken or wiring faulty
1Water pressure switch open
1.0See fault 05.
1.1Communication error.
1.2Internal fault mcba.
1.3See fault 05
1.4Internal fault mcba.
1.5See fault 05.
1.6See fault 05.
1.7See fault 03.
1.8Flow temperature too high.
1.9Return temperature too high.
10Return NTC
10124 V short circuit
11No signal on main board. Check wiring and user interface. If in order, replace the main board. Fan defect. Replace fan
12No signal on user interface
13Incorrect cylinder setting parameter / main board fault
14Flow temperature greater than 95°C
15Stepper motor fault diverter valve
16Incorrect flame detection
17Insufficient mains voltage < 170 V ~
17 FInsufficient mains voltage < 170 V ~ Faulty fuse Check the transformer, fuse and wiring. Replace the transformer if necessary Faulty main PCB Replace main PCB
18(no change)
18There is a fault in the user interface.
19Flow NTC fault, dT > 35K 10 times in succession
2Air pressure switch not in rest position
2.1Flow temperature deviation.
2.2Return temperature deviation.
2.4Return temperature higher than flow temperature.
2.5See fault 18.
2.6Short circuit in wiring harness.
2.8No feedback from fan to mcba.
2.9See fault 28.
20Software not compatible
20 FSoftware not compatible
202No flame formation
21System water pressure too low
21 FSystem water pressure too low
22System water pressure too high
22 FSystem water pressure too high
24Return temperature > 90°C. Insufficient or no circulation. See F 5. System resistance too high, bypass insufficient.
24 FReturn temperature > 90 C Insufficient See F 05 circulation or system resistance too high, no circulation bypass insufficient
25Rise in flow temperature too fast
25Flow temperature rising too quickly. See F 05. System resistance too high, bypass insufficient
25 FRise in flow temperature too fast See F 05 System resistance too high, bypass insufficient
26Temperature difference between flow and return temperature too large in central heating mode
26Temperature difference between flow and return temperature too large in CH mode.
26 FTemperature difference between flow and return temperature too large in central heating mode See F 05 System resistance too high, bypass insufficient
3Air pressure switch does not switch on (after 120 sec.)
3.0See fault 18.
3.1Flow NTC short-circuited.
3.2Return NTC short-circuited.
3.6Flow NTC open circuit.
3.7Return NTC open circuit.
4CH temperature sensor NTC defective
4.1See fault 05.
4.2See fault 05.
4.3See fault 05.
4.4See fault 05.
403Control fault
404Control fault
405Control fault
406Control fault
407Control fault
410Control fault
411Control fault
413Control fault
414Control fault
415Control fault
416Control fault
417Control fault
424Control fault
426Control fault
429Control fault
430Control fault
431Control fault
432Control fault
436Control fault
437Control fault
441Control fault
5DHW temperature sensor NTC defective
508Air transport
528Air transport
6Gas valve defective
6.0Internal fault mcba.
6.1Air pressure switch not in rest position.
8Internal fault
9Dipswitch 3 not in correct position
912Maximum limit/water shortage
918Maximum limit/water shortage
919Maximum limit/water shortage
925Maximum limit/water shortage
AGas valve control circuit fault
BCylinder demand (only for 23.38W with cylinder)
CCH demand
C.Control stop: CH water temperature higher than set value
EPump control circuit fault
E 05Communication error on central control of the modules
E 101The specified number of modules does not match the number of modules detected
E 11Communication error on the boiler bus (X7) flat cable faulty or poorly connected, central control of the faulty module.
E 15Fault in the central control MBD of the modules.
E 18The temperature in the boiler outlet pipe is > 95 C. heating due to heat demand, but no heat being drawn off (e.g. because the cylinder charging pump is faulty).
E 19The temperature in the boiler outlet pipe is > 95 C. heating due to heat demand, but no heat being drawn off (e.g. because the cylinder charging pump is faulty).
E 26Open circuit at the air pressure switch, low water pressure protection or selector switch (terminals 23/24). Is the system working pressure correct? (2 bar)
E 31Short circuit in the boiler's global flow temperature sensor (NTC). Faulty cable, poor connector contact, moisture, faulty NTC.
E 32Short circuit in the boiler's global flow temperature sensor (NTC). Faulty cable, poor connector contact, moisture, faulty NTC.
E 36Short circuit in the boiler's global flow temperature sensor (NTC). Faulty cable, poor connector contact, moisture, faulty NTC.
E 37Open circuit at the temperature sensor (NTC) in the boiler return pipe
E 43EEPROM fault
E 60Parameters outside the permitted control range
E 90Detection of the controller interface (AM4) impossible
E 91Detection of the expansion board of the central boiler control.
E 92Fault on all modules
FPump switched on at 7C contact
F 0No fault
F 1Ignition fault
F 1Ignition fault. No flame detection No gas / gas valve closed: Check the gas connection / gas valve and the inlet pressure. No ignition: Check the ignition electrode and wiring.
F 10Return NTC is broken or wiring faulty
F 10Return NTC
F 11No signal on main board. Check wiring and user interface. If in order, replace the main board. Fan defect. Replace fan
F 11No signal on main board Check wiring and user interface. If in order, replace the main board. Fan fault.
F 11No signal on main board Check wiring and user interface. If in order, replace the main board. Fan fault. Replace fan
F 11No signal on main board Check wiring and user interface. If in order, replace the main board. Fan fault. Replace fan
F 12No signal on user interface Check wiring and main board. If in order, replace the user interface.
F 12No signal on user interface Check wiring and main board. If in order, replace the user interface.

Order parts for your AWB boiler

AWB parts are available from Instalpunt; shipping to EU countries from €12.95 (€16.95 for more distant countries), usually 3–5 working days.

View AWB parts →

Frequently asked questions about AWB faults

What does a fault on an AWB boiler mean?

The appliance is reporting that it has shut itself down or cannot continue. The code on the display points to the group of causes: ignition, water pressure, a sensor, the fan or communication with the thermostat. The table above shows, for each code, what AWB means by it.

How do I reset my AWB boiler?

The reset button is on the control panel of your AWB boiler; on most appliances you hold it down for two to five seconds until the display responds. Reset once. If the same fault comes straight back, resetting will not solve it and a part or a setting needs attention. Always consult the manual for your model: the position of the button and how long to press it differ per series.

Can I fix an AWB fault myself?

You can top up the water pressure, bleed the system, replace filters and clean a siphon yourself. Anything behind the sealed section of a gas appliance is a different matter: work on the gas valve, burner, heat exchanger and flue must be carried out by a certified gas engineer.

How much does it cost to fix a fault?

That depends on the cause and whether a part is needed. With us you can see the part straight away with its price and delivery time, so you know where you stand in advance. If you call in an engineer, always ask about the call-out charge and hourly rate before they come.

Where can I find the right part for my AWB?

Check the rating plate for the exact type and use it to search our catalogue, or search directly by the manufacturer number of the faulty part. Each part lists the appliances it fits.