Boiler with display and pressure gauge
Boiler fault codes

Eco Heating Systems boiler faults: fault codes, causes and parts

All 73 fault codes for Eco Heating Systems boilers, plus the faults that show no code. Type your code or choose your symptom.

In brief

A fault on an Eco Heating Systems boiler usually means that the appliance has locked out or is reporting a fault code. Note the code on the display and look it up below: for each code you will find its meaning, checks you can safely do yourself and the parts that are often checked or replaced. Frequently searched: 4 (lockout code active for more than 20…), 14 (no air transport to the burner), 129 (faulty DHW sensor or short circuit). No code? Check the water pressure (1.5 to 2 bar when cold), the power supply and the gas tap, and reset once. If the fault comes back, call in a certified gas engineer. If you smell gas, call your national gas emergency number or 112 immediately.

Most searched Eco Heating Systems faults

These are the codes that visitors to this site search for most often.

See the 25 most searched fault codes of 2026, with the figures behind them →

Eco Heating Systems boiler faults without a code on the display

Not every fault shows a code. These are the symptoms we come across most often with Eco Heating Systems appliances, with what you can check yourself before calling someone out.

No hot water, but the heating works

The boiler heats the radiators but not the tap water. Check that the hot water function is switched on in the display (on some appliances it is called DHW mode or summer mode) and that the hot water valve under the boiler is open. If the water stays cold, this usually points to a fouled or leaking DHW heat exchanger, a faulty diverter valve or a DHW sensor giving incorrect readings. View the matching parts → Read the full explanation: no hot water, six causes →

Water pressure keeps dropping

Top up to 1.5–2 bar when cold and bleed the radiators. If the pressure drops again within a few days, the expansion vessel has often lost its pre-charge or there is a small leak in the system. A pressure relief valve that keeps dripping gives the same symptom. View the matching parts → Read the full explanation: water pressure keeps dropping – expansion vessel or leak? →

Boiler shuts down and locks out

The appliance shuts down and only starts again after a reset. Reset once; if the fault comes straight back, leave the reset button alone. Repeatedly resetting a locked-out boiler is not without risk: the safety device trips for a reason. View the matching parts → Read also: is the boiler cutting out because of a sensor or overheating? →

Radiators stay cold

Check that the thermostat is calling for heat, that the radiator valves are open and that the system has enough pressure. If everything stays cold while the boiler is firing, the circulation pump is often not running or the diverter valve is stuck in the hot water position. View the matching parts → Read the full explanation: radiators stay cold →

Ticking, humming or boiling noise

A banging noise at start-up usually points to air or limescale in the heat exchanger. A humming pump may have a worn bearing. A rattling fan is often rubbing or dirty. View the matching parts → Read also: replacing the fan – what to rule out first →

Water under the boiler

Check where it is coming from: the condensate drain (siphon blocked or cracked), the pressure relief valve (pressure too high or faulty expansion vessel) or a fitting. If in doubt, switch the boiler off and close the water supply. View the matching parts → Read the full explanation: water under the boiler – condensate or a leak? →

All 73 Eco Heating Systems boiler fault codes

CodeCause
0Incorrectly programmed BCU or PB.
1No gas, incorrectly adjusted gas valve.
10Incorrectly programmed BCU or PB.
100Incorrectly programmed BCU or PB.
101Incorrectly programmed BCU or PB.
102Incorrectly programmed BCU or PB.
103Incorrectly programmed BCU or PB.
104Incorrectly programmed BCU or PB.
105Too little water through the heat exchanger.
106Incorrectly programmed BCU or PB.
107Incorrectly programmed BCU or PB.
108Incorrectly programmed BCU or PB.
109Incorrectly programmed BCU or PB.
11Incorrectly programmed BCU or PB.
110Incorrectly programmed BCU or PB.
111Incorrectly programmed BCU or PB.
112Incorrectly programmed BCU or PB.
113Incorrectly programmed BCU or PB.
114Incorrect earthing of BCU and boiler.
116Water pressure too low.
118Incorrectly programmed BCU or PB.
119Faulty return sensor or not connected.
12Incorrectly programmed BCU or PB.
120Faulty flow sensor or not connected.
122Faulty hot water sensor or not connected.
123Faulty flue gas sensor or not connected.
125Faulty outdoor sensor or not connected or incorrect heating mode programmed.
126Faulty return sensor or short circuit.
127Faulty flow sensor or short circuit.
129Faulty DHW sensor or short circuit.
13Electrical circuit is short-circuited or APS is faulty.
130Faulty flue gas sensor or short circuit.
132Faulty outdoor sensor or short circuit.
134Reset several times by user or installer.
136Water temperature is higher than 90 ⁰C.
14No air transport to the burner; flue gas or air inlet is blocked or APS is faulty or air signal hose is not connected to the air inlet pipe or water in the hose.
15Burner door clixon activated by overheating of the burner door or restricted water flow through the heat exchanger or the thermal fuse of the rear wall has been activated because the insulation disc of the rear wall (combustion chamber) is damaged or broken.
155Incorrectly programmed BCU or PB.
16There is no water in the heat exchanger or the flue gas sensor is not working or the heat exchanger is overheated.
162The water pressure is below the minimum pressure level.
164Not enough water is flowing through the heat exchanger.
168Flue gas side blockage of the heat exchanger.
17Incorrectly programmed BCU or PB.
18Incorrectly programmed BCU or PB.
19Incorrectly programmed BCU or PB.
2Short circuit in the gas valve coil, water on wiring or gas valve.
20Incorrect earthing of BCU and boiler.
200Connection between cascade boilers is interrupted or the wiring is broken or parameter 147 of the lead boiler is set incorrectly.
202Incorrectly programmed parameter.
203Connection between cascade boilers is interrupted or the wiring is broken.
204Faulty outdoor sensor or not connected or incorrect heating mode selected.
205Faulty system sensor or not connected.
206Faulty cascade sensor or not connected.
207Heat-exchanger protection active.
21Incorrect earthing of BCU and boiler.
22Poor gas supply or O2 level in flue gas is incorrect or faulty ignition electrode.
23Incorrectly programmed BCU or PB.
27If the output is programmed for a filling valve and there are too many filling attempts.
28If the output is programmed for a filling valve and filling takes more than 10 minutes.
29Incorrectly programmed BCU or PB.
3Short circuit in the gas valve coil, water on wiring or gas valve.
30Incorrectly programmed BCU or PB.
32There is not enough water flow through the heat exchanger.
33There is no water in the heat exchanger or it is not electrically connected.
34There is no water in the heat exchanger or it is not electrically connected.
35No air transport to the burner after heat demand; flue gas or air inlet is blocked or APS faulty or air signal hose not connected to the air inlet pipe or water in the hose.
36Incorrect gas pressure at the gas supply; loose wire in connection terminal.
4Lockout code active for more than 20 hours.
5Electrical wiring not connected correctly or fan not working properly.
6Electrical wiring not connected correctly or fan not working properly.
7Electrical wiring not connected correctly, or fan not working properly.
8Incorrectly programmed BCU or PB.
9Outdated EEPROM.

Order parts for your Eco Heating Systems boiler

Eco Heating Systems parts are available from Instalpunt; shipping to EU countries from €12.95 (€16.95 for more distant countries), usually 3–5 working days.

View Eco Heating Systems parts →

Frequently asked questions about Eco Heating Systems faults

What does a fault on an Eco Heating Systems boiler mean?

The appliance is reporting that it has shut itself down or cannot continue. The code on the display points to the group of causes: ignition, water pressure, a sensor, the fan or communication with the thermostat. The table above shows, for each code, what Eco Heating Systems means by it.

How do I reset my Eco Heating Systems boiler?

The reset button is on the control panel of your Eco Heating Systems boiler; on most appliances you hold it down for two to five seconds until the display responds. Reset once. If the same fault comes straight back, resetting will not solve it and a part or a setting needs attention. Always consult the manual for your model: the position of the button and how long to press it differ per series.

Can I fix an Eco Heating Systems fault myself?

You can top up the water pressure, bleed the system, replace filters and clean a siphon yourself. Anything behind the sealed section of a gas appliance is a different matter: work on the gas valve, burner, heat exchanger and flue must be carried out by a certified gas engineer.